Connecting The Valve Position Transducer - Bosch Rexroth VT-VRPD-2 Installation & Operation Manual

Digital valve amplifier for valve types, 4wre 6 & 10, component series 2x
Table of Contents

Advertisement

RE 30126-B/09.13 | Installation and Operation
2.8

Connecting the valve position transducer

Connection for the valve position transducer is shown in the following illustration.
Valve position feedback connection
Fig. 5 Connecting the valve transducer
The transducer is connected using a 4-pole cable connector Pg7-G5W1F, which can
be ordered separately under material number R900023126.
Cable 4 x 0.25 mm² of type LiYCY-CY ( 4 x 30 AWG Double shielded cable) is rec-
ommended for lengths up to 50 m.
The shield should be connected to z10 on the edge connector of the controller on the
supply side only.
Hydraulics | Bosch Rexroth AG
4 2
1
3
19/32
Installing the VRPD 2
z14
z12
z16
z18
z10