Installing Und Connecting The Vt-Ssv-1-2X; Connecting The Supply Voltage; Suppressing Interference Of The System - Bosch rexroth VT-SSV-1 Operating Instructions Manual

Plug-in switching amplifier
Table of Contents

Advertisement

Installation | Plug-in switching amplifier VT-SSV
7.3

INSTALLING UND CONNECTING THE VT-SSV-1-2X

The dimensions of plug-in switching amplifier VT-SSV-1-2X are given in data sheet
RE 30262.
Assemble the unit using a plastic cable gland PG11 with inserted seal. The
clamping range is 7.6 ... 11.5 mm
The required tightening torque for flat head screw M3 is 0.5 Nm, for clamping
screw M2,6 max. 0.4 Nm.
Proceed as follows to assemble the VT-SSV-1-2X:
1. Loosen the flat head screw and open the cover.
2. Lead the connection cable through the plastic cable gland PG11.
3. Fasten the connection cable with the help of the clamping screws.
4. Tighten plastic cable gland PG11.
5. Close the cover and tighten the flat head screw to the specified tightening
torque.
7.4

CONNECTING THE SUPPLY VOLTAGE

1. Disconnect the relevant system part from the power supply.
2. Inspect all cables for intactness.
3. Connect the signal and solenoid cables according to your circuit diagram to the
relevant terminals of the VT-SSV-1-2X.
4. Connect the supply voltage and check the presence of voltage by switching on.
Tabelle 6: Cable variant
Connection cable
Single-wire
Ultrafine-wire
With wire end ferrule
For cable gland PG11 the hole in the cover is expanded to ⌀ 12.
The stripped length is 5 mm.
7.4.1

Suppressing interference of the system

Should interference occur in conjunction with signals of the VT-SSV-1-2X, check
the interference suppression of other electrical components, e.g. as follows:
Tabelle 7: Suppressing interference
Possible causes of faults
Switched inductance
Electric motors
Frequency converter
Cross-
section
2.5 mm²
1.5 mm²
1.5 mm²
DC: antiparallel free-wheeling diode over actuator winding
AC: type-related R/C combination over actuator winding.
R/C combination from each motor winding to earth.
Inlet filter in the voltage supply of the frequency converter
Motor control lines shielded and installed separately from other
cables and/or output filter for motor cables.
Large-area contact of the frequency converter housing to the
rear wall of the control cabinet
RE 30262-B, Edition 05.2022, Bosch Rexroth AG