7�3 Installation position
The analog amplifier must be installed so that the connector is positioned
vertically downwards.
The cable must be routed so that it lies completely or partially below the amplifier
connection (see Fig. 6).
The IP65 type of protection is only achieved in the shown installation position in
combination with a sealing of the connector relative to the wire harness sleeve.
Any ingress of water into the analog amplifier by way of the wire harness must be
avoided by routing the wire harness accordingly.
Fig� 6: Installation position analog amplifier
7�4 Mounting the analog amplifier
7�4�1 Preparation
1� Use the material number on the sticker of the packaging unit or directly on the
analog amplifier to check whether the correct analog amplifier is available,
see chapter 4 "Scope of delivery" on page 13.
2� Compare the material number with the details in the order confirmation.
If the material number of the analog amplifier does not match the one in the
order confirmation, contact your local contact person for clarification.
You can find their contact information at
https://addresses.boschrexroth.com
7�4�2 Mounting
The RA analog amplifier has mounting lugs for assembly.
Use M6 screws (no countersunk head). Washers are absolutely necessary.
Tighten the screws with a torque of 4 Nm.