Connections And Settings; Connecting Inputs; Priority Microphone (Input 1) - Bosch Plena PLE-1MA030-US Installation And User Instructions Manual

Plena mixer amplifier
Hide thumbs Also See for Plena PLE-1MA030-US:
Table of Contents

Advertisement

Plena Mixer Amplifier | Installation and User Instructions | Connections and settings
4

Connections and settings

4. 1

Connecting inputs

4.1.1

Priority microphone (input 1)

The priority microphone (or a generic call station) that
can be used with push to talk (PTT) should be
connected to "microphone/line 1 input". The PTT
mode can be activated by setting the DIP switch (11) at
the rear of the unit. Microphone/line 1 input has
priority over all other microphone/line inputs.
If, however, the "Tel. emergency/70V input" receives a
signal, all inputs including microphone/line 1 input will
be overruled.
The microphone/line 1 input has a Euro style pluggable
screw terminal connector. This Euro style pluggable
screw terminal connector has a trigger input, which can
be used in combination with the Euro connector.
The priority microphone can be connected to the
microphone/line 1 input with trigger as follows:
Euro connector with trigger. See figure 4.1.
Euro connector only (without trigger).
Set the DIP switch settings for microphone/line 1 with
trigger, as required. See section 4.3.
Note
When connecting an unbalanced line level
(200 mV) signal to the microphone/line input,
connect it as follows: Signal to +, connect to -
and GND to ground.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
figure 4. 1 : Euro connector with trigger
en | 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plena ple-1ma120-usPlena ple-1ma060-us

Table of Contents