11.2

EQUIPMENT WARNING LABELS

MATERIAL - VINYL OR POLYESTER
DO NOT attempt to install, operate, maintain or dispose of this equipment until you have read and under-
TEMPERATURE - MINUS 20 TO 100 deg. C
stood all of the product warnings and user directions that are contained in this instruction manual.
ADHESIVE - V23 OR EQUIV.
MUST RESIST OIL SOLVENTS
FIgure 11-2 shows examples of warning labels that may be found attached to the equipment. DO NOT
ALL MATERIALS USED MUST
BE UL RECOGNIZED
remove or cover any of the labels. If the labels are damaged or if additional labels are required, contact
your TOSHIBA representative for additional labels.
WARNING AREA BACKGROUND COLOR: ANSI DANGER RED
WARNING AREA TEXT COLOR: ANSI WHITE
The following are examples of the warning labels that may be found on the equipment. The labels are
TEXT AREA BACKGROUND COLOR: ANSI WHITE
TEXT AREA TEXT COLOR: ANSI BLACK
there to provide useful information or to indicate an imminently hazardous situation that may result in seri-
CORNER RADIUS: VENDOR STANDARD
ous injury, severe property and equipment damage, or death if the instructions are not followed.
(A) 40308
4.50
Only qualified technicians familiar with this equipment and the
information supplied with it should be permitted to install and
operate this equipment.
Installation of electrical equipment must be done in
accordance with National Electrical Code and any other state
or local codes. Proper grounding and conductor sizing must
be installed for safe operation.
During operation, keep all covers in place and cabinet
MATERIAL - VINYL OR POLYESTER
doors shut.
EMPERATURE - MINUS 20 TO 100 deg. C
When performing visual inspections and maintenance, if
ADHESIVE - V23 OR EQUIV.
possible, be sure the MBS is turned off and the incoming
MUST RESIST OIL SOLVENTS
AC feed is turned off and locked out.
ALL MATERIALS USED MUST
The UPS and Battery Cabinet will have hazardous
BE UL RECOGNIZED
voltages present even after the AC feed is turned off.
WARNING AREA BACKGROUND COLOR: ANSI DANGER RED
If it is necessary to make measurements with the power
WARNING AREA TEXT COLOR: ANSI WHITE
on, do not touch any electrical connection points. Remove
all jewelry from wrists and fingers. Make sure test equipment
EXT AREA BACKGROUND COLOR: ANSI WHITE
is in good, safe operating condition.
EXT AREA TEXT COLOR: ANSI BLACK
CORNER RADIUS: VENDOR STANDARD
While servicing, stand on some type of insulation, and be
sure not to be grounded.
MATERIAL - VINYL OR POLYESTER
Follow the safety instructions given in the equipment manual
TEMPERATURE - MINUS 20 TO 100 deg. C
carefully and observe all danger, warning and caution notices.
ADHESIVE - V23 OR EQUIV.
MUST RESIST OIL SOLVENTS
0.00
ALL MATERIALS USED MUST
(C) 43784
BE UL RECOGNIZED
WARNING AREA BACKGROUND COLOR: ANSI DANGER RED
1.50
WARNING AREA TEXT COLOR: ANSI WHITE
TEXT AREA BACKGROUND COLOR: ANSI WHITE
TEXT AREA TEXT COLOR: ANSI BLACK
CORNER RADIUS: VENDOR STANDARD
0.00
(E) 48082
DRAWN:
CHECKED:
1.50
WLM 3-9-11
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF TOSHIBA INTERNATIONAL
CORPORATION AND SHALL NOT BE REPRODUCED, USED, OR DISCLOSED
TO OTHERS UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED.
N
DATE
BY
13131 WEST LITTLE YORK ROAD, HOUSTON, TX 77041 U.S.A.
0.00
4300 Series Ancillary Cabinets Installation and Operation Manual
DANGER
HAZARDOUS VOLTAGES
Hazardous voltages are used in the operation
of this equipment and could cause severe personal
injury or loss of life.
The following precautions should be observed to
reduce the risk of injury or death.
DANGER
WARNING AREA
This unit contains sealed lead acid batteries.
DC VOLTAGE
Lack of preventative maintenance could result
TEXT AREA
DC Voltage supplied by batteries is still
in batteries exploding and emitting gasses and/or
flame. Annual preventative maintenance must be
present after equipment has been
performed by an authorized, trained technician.
turned off and taken off line.
Accidental contact with live parts can
cause personal injury and death.
Disconnect all DC Sources before
performing any service or testing
in this compartment.
43784
This unit contains sealed lead acid batteries.
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
TITLE:
APPROVED:
flame. Annual preventative maintenance must be
ZIR 3-10-11
WLM 3-10-11
performed by an authorized, trained technician.
DANGER
WARNING AREA
TEXT AREA
AC VOLTAGE
This UPS receives power from more
than one source. Disconnect all AC
This unit contains sealed lead acid batteries.
sources before performing any service
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
or testing inside this unit
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
48082
Figure 11-2: Battery Cabinet Warning Labels
This unit contains sealed lead acid batteries.
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
(B) 41750
WARNING AREA
TEXT AREA
PN 41750
40308
64818
PRINT - BLACK
(D) 49455
MATERIAL - UL APPROVED - 3M 7883
ADHESIVE - UL APPROVED - 3M 300
WARNING
ECO 77296
07-09
ECN
DATE
WARNING
(F) 66005
DANGER LABEL
32° AMBIENT
GENERAL - MBS
TEMPERATURE
WARNING
DRAWING NO.:
64818
WARNING
WARNING
4.00
WARNING - Risk of electric shock
DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
HAZARDOUS LIVE PARTS INSIDE THIS UPS ARE ENERGIZED
FROM THE BATTERY SUPPLY EVEN WHEN THE INPUT AC POWER
IS DISCONNECTED.
CAPACITORS STORE HAZARDOUS ENERGY. DO NOT REMOVE
COVER UNTIL 5 MINUTES AFTER DISCONNECTING ALL SOURCES
OF SUPPLY.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, INSTALL
IN A TEMPERATURE AND HUMIDITY CONTROLLED INDOOR
AREA FREE OF CONDUCTIVE CONTAMINANTS.
AVERTISSEMENT
'
EN CAS D UTILISATION EN ATMOSPHERE CONTROLEE.
CONSULTER LA NOTICE TECHNIQUE.
BATTERY BACK-UP TIME, WHICH WAS FACTORY-SET AT A
PREDETERMINED LEVEL, DECREASES GRADUALLY BETWEEN
SERVICE PERIODS. THE BATTERIES SHOULD BE REPLACED
EVERY THREE YEARS AFTER THE LAST SERVICING, THE DATE
OF WHICH IS WRITTEN ON THE ID PLATE LOCATED ON THE
REAR SIDE OF THE UPS UNIT, OR IN THE BOX BELOW.
DATE OF LAST BATTERY CHARGE:
10.40"
WARNING
TITLE:
DRAWN:
CHECKED:
APPROVED:
TF 9-8-94
AMB 07-09
AMB 07-09
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF TOSHIBA INTERNATIONAL
CORPORATION AND SHALL NOT BE REPRODUCED, USED, OR DISCLOSED
TO OTHERS UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED.
This unit contains sealed lead acid batteries.
ZIR
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
BY
13131 WEST LITTLE YORK ROAD, HOUSTON, TX 77041 U.S.A.
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
1.00"
WARNING
This unit contains sealed lead acid batteries.
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
SCALE:
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
FULL
0
REV:
WARNING
This unit contains sealed lead acid batteries.
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
WARNING
This unit contains sealed lead acid batteries.
Lack of preventative maintenance could result
in batteries exploding and emitting gasses and/or
flame. Annual preventative maintenance must be
performed by an authorized, trained technician.
WARNING
4.00
WARNING
SCALE:
CAUTION LABEL
3=2
CRITICAL FUSE SIZING
10-18KVA UPS
Incorrect fuse replacement size
1
REV:
may result in fire or inadequate
equipment protection.
DRAWING NO.:
41750
Replace only with same type
and rating of fuse.
WARNING
CRITICAL FUSE SIZING
Incorrect fuse replacement size
may result in fire or inadequate
equipment protection.
Replace only with same type
and rating of fuse.
WARNING
CRITICAL FUSE SIZING
Incorrect fuse replacement size
may result in fire or inadequate
equipment protection.
Replace only with same type
and rating of fuse.
WARNING
CRITICAL FUSE SIZING
Incorrect fuse replacement size
may result in fire or inadequate
equipment protection.
Replace only with same type
and rating of fuse.
WARNING
33
CRITICAL FUSE SIZING
Incorrect fuse replacement size
may result in fire or inadequate
equipment protection.
Replace only with same type
and rating of fuse.
WARNING