4. Be sure to install a lightning arrestor on the Ethernet cable between the bridge and
power injector. The lightning arrestor should be placed outdoors, immediately before
the Ethernet cable enters the building.
Informational Note:
national electrical codes. For additional lightning protection, use lightning rods, lightning
arrestors, or surge suppressors.
Connecting the Power Supply Unit
To connect the wireless bridge to a PSU:
Informational Note:
over Ethernet (PoE) based on the IEEE 802.3af standard. Do not try to power the unit by
connecting it directly to a network switch that provides IEEE 802.3af PoE. Always connect
the unit to the included power injector module.
Informational Note:
Networks-approved WLA-XPS9001GO outdoor power supply in order to prevent possible
damage to the unit.
1. Connect the Ethernet cable from the wireless bridge to the PoE port labeled "DATA
PWR OUT" on the PSU.
Informational Note:
2. The WLA-XPS9001GO PSU is shipped with an North American (NA) power cable
connected to the standard AC receptacle on the PSU. For international users, install
your own nationally-approved AC plug to the power cable.
3. Plug the other end of the power cable into a grounded, 3-pin socket, AC power
source.
Informational Note:
appropriate for your country.
Copyright © 2012, Juniper Networks, Inc.
Be sure that grounding is available and that it meets local and
The Ethernet port on the wireless bridge does not support Power
The WLA622 and WLA632 must only be used with a Juniper
The DATA IN port on the PSU is not used.
International users must use a nationally approved AC plug