3. Solder the ground wire to the ground-wire terminal lug supplied with the lightning
arrestor. Juniper Networks recommends that you use 6-gauge cable for the ground
wire. The ground wire must be properly earthed in order to provide adequate
protection.
4. Attach the ground-wire terminal lug, lock washer, and hex nut to the lightning
arrestor, in the order shown in the figure below.
Informational Note:
antenna specified with the set ap radio antenna type command exactly matches the
external antenna attached to the WLA620 external antenna port.
Figure 3–4. Attaching the Ground-Wire Terminal Lug, Lock Washer, and Hex Nut to the
Lightning Arrestor
Lightning Protector
a. Connect one end of the short RF coaxial cable to the WLA620 N-type connector,
b. Connect one end of the 3m RF coaxial cable to the lightning arrestor, and
5. Connect the antenna to the WLA620 N-type connector using the RF coaxial cable
provided in the antenna package.
6. Apply weatherproofing tape to the antenna connectors to help prevent water
entering the connectors.