3. Pan the antenna horizontally back and forth while checking the RSSI voltage. If
using the pole-mounting bracket with the WLA620, you must rotate the mounting
bracket around the pole. Other external antenna brackets may require a different
horizontal adjustment.
4. Find the point where the signal is strongest (highest voltage) and secure the
horizontal adjustment in that position.
Informational Note:
because vertical alignment is too far off and only two similar peaks for the side lobes are
detected. In this case, fix the antenna so that it is halfway between the two peaks.
5. Loosen the vertical adjustment on the mounting bracket and tilt the antenna slowly
up and down while checking the RSSI voltage.
6. Find the point where the signal is strongest and secure the vertical adjustment in
that position.
7. Remove the voltmeter cable and replace the connector cover.
Copyright © 2012, Juniper Networks, Inc.
RSSI BNC
Connection
Sometimes there may not be a central lobe peak in the voltage
Installing and Connecting an Access Point
Voltmeter