a. Solder the ground wire to the ground-wire terminal lug supplied with the lightning
b. Attach the ground-wire terminal lug, lock washer, and hex nut to the lightning
Informational Note:
antenna specified with the set ap radio antennatype command exactly matches the
external antenna attached to the WLA622 external antenna port.
Figure 3–13. Attaching the Ground-Wire Terminal Lug, Lock Washer, and Hex Nut to
the Lightning Arrestor
Lightning Protector
c. Connect one end of the short RF coaxial cable to the WLA622 N-type connector,
d. Connect one end of the 3m RF coaxial cable to the lightning arrestor, and
3. Connect the antenna to the WLA622 N-type connector using the RF coaxial cable
provided in the antenna package.
4. Apply weatherproofing tape to the antenna connectors to help prevent water
entering the connectors.
Copyright © 2012, Juniper Networks, Inc.
arrestor. Juniper Networks recommends that you use 6-gauge cable for the
ground wire. The ground wire must be properly earthed in order to provide
adequate protection.
arrestor, in the order shown in Figure 3–4 below.
To meet regulatory requirements, you must ensure that the external
Grounding Nut
To MP-632
6-gauge
Grounding Cable
and connect the other end to the lightning arrestor.
connect the other end to the outdoor antenna. Continue with step 6.
Installing and Connecting an Access Point
Locking Washer
Hex Nut
To External Antenna