Download Print this page

Technical Specifications - HP ProLiant DL160 Quickspecs

Hp proliant dl160 generation 8 (gen8)
Hide thumbs Also See for ProLiant DL160:

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
System Inlet
Temperature
DA - 14282 Worldwide — Version 22 — December 13, 2013
HP ProLiant DL160 Generation 8 (Gen8)
4 LFF
8 SFF
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-energy-efficient
Or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL160 G8
- Follow the instructions of the next screens.
Rated Steady-State Power 500 Watts (at 100 VAC),
Maximum Peak Power
(See Power Specifications
Tables)
Operating
1.7" (43.2mm) Height x 17.1" (434.6mm) Width x
29.5" (750mm) Length
1.7" (43.2mm) Height x 17.1" (434.6mm) Width x
27.5" (699mm) Length
33..00 lb (15.2kg)
31 lb (14.1kg)
100 to 120 VAC, 200 to 240 VAC
10 A at 100 VAC
5 A at 200 VAC
50 Hz to 60 Hz
562 W at 100V AC input
562 W at 200V AC input
500W
1917 at 100 V AC
1898 at 115 V AC
1856 at 200 V AC
1850 at 230 V AC
460W
1764 at 100V AC
1736 at 115V AC
1694 at 200V AC
1687 at 230V AC
750W
2878 at 100 V AC
2834 at 115 V AC
2769 at 200 V AC
2758 at 230 V AC
500 Watts (at 200 VAC)
500Watts (at 100 VAC),
500 Watts (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
Page 55

Advertisement

loading

This manual is also suitable for:

Proliant dl160 gen8Proliant dl160 generation 6