7.31 START/STOP UNIT (1B)

Byte
7
6
0
1
LUN
2
3
4
5
VU = 0
Figure 113. START/STOP Unit (1B)
The START/STOP UNIT command is used to spin up or stop the spindle motor.
Immed bit is to specify
0
Status is to be returned at the end of the operation.
1
G O O D status shall always be returned immediately after command has been received. The TEST
UNIT READY command may be used to determine when the file becomes ready after a spin-up.
Start bit is to specify:
0
Stop the spindle.
1
Start the spindle.
Note: Once the drive has become ready (after a power on ) the Start/Stop UNIT command can be used
without any errors, regardless of the state of the motor, stopped or spinning.
Bit
5
4
3
Command Code = 1Bh
Reserved = 0
Reserved = 0
Reserved = 0
Reserved = 0
2
1
0
Immed
Start
FLAG
LINK
SCSI C O M M A N D SET
147