IBM DDRS-39130 - Ultrastar 9.1 GB Hard Drive Specifications page 219

3.5-inch hard disk drive ( 9130 / 4560 mb )
Hide thumbs Also See for DDRS-39130 - Ultrastar 9.1 GB Hard Drive:
Table of Contents

Advertisement

Key
Code
Qual
2h
40h
85h
3h
0Ch
03h
3h
10h
00h
3h
11h
00h
3h
14h
01h
3h
16h
00h
3h
19h
00h
3h
31h
01h
4h
11h
00h
4h
19h
00h
4h
32h
00h
4h
40h
80h
4h
40h
85h
4h
44h
00h
4h
81h
00h
5h
1Ah
00h
5h
20h
00h
5h
21h
00h
5h
24h
00h
5h
25h
00h
5h
26h
00h
6h
28h
00h
6h
29h
00h
6h
2Ah
00h
6h
2Ah
02h
6h
2Fh
00h
6h
3Fh
01h
6h
5Dh
00h
Bh
00h
00h
Bh
1Bh
00h
Description
Diag Fail - R A M Microcode Not Loaded.
Medium error. Recommend Reassign.
Medium error. ID C R C error.
Medium error. Unrecovered read error.
Medium error. Record not found.
Medium error. Data synchronization mark error. (DAM error)
Medium error. Defect list error. A defect list error occurs when a data error
is detected while reading the manufacturing defect list or while reading or
writing the grown defect list.
Medium error. Medium Format Corrupted Reassign Failed
Hardware Error. Unrecovered read error in reserved area.
Hardware Error. Defect list error.
Hardware Error. No defect spare location available. A "no defect spare
location available sense code" indicates that the Reassign Block command
can not proceed the process because all spare sectors have been used, or it
will exceed implementation limitation of defect handling of the file.
Degrade Mode. Diagnostic Fail. Configuration sector valid check fail.
Reserved area sector valid check fail.
Degrade Mode. R A M Microcode Not Loaded.
Hardware Error. Internal target failure.
Hardware Error. Internal logic error.
Illegal request. Parameter list length error. The number of parameters sup-
plied is not equal to the value the expected.
Illegal request. Illegal command operation code. This command is also
returned when an unsupported command code is received.
Illegal request. Logical block address out of range.
Illegal request. Invalid field in CDB.
Illegal request. Invalid lun.
Illegal request. Invalid fields in the parameter list.
Unit attention. Not ready to ready transition.(Format completed)
Unit attention. Power on reset or Bus device reset occurred.
Unit attention. Parameters changed.
Unit attention. Log select parameters changed.
Unit attention. Command cleared by another initiator.
Unit attention. Micro code has been changed.
Predictive Failure Analysis threshold reached on
Aborted command. No additional sense code.
Aborted command. Synchronous data transfer error. (Extra ack detected)
209
SCSI SENSE DATA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddrs-34560

Table of Contents