SECURITY LOCK SET SETTING
C
Recording and playback operating privilege
setting
Selection of operating privilege
The available operations vary depending on the ON/OFF and
ADMIN/USER settings.
Selection
conditions
All operations are locked. When the user password
is entered at the password entry screen, only
playback operations can be carried out. When the
Administrator password is entered, all operations
can be carried out.
All operations are locked. When the user password
is entered at the password entry screen, only
playback and recording operations can be carried
out. When the Administrator password is entered,
all operations can be carried out.
Recording and menu operations are locked.
Playback operations are not locked. When the
Administrator password is entered, all operations
can be carried out.
Menu operation is locked. Recording and playback
operations are not locked. When the Administrator
password is entered at the password entry screen,
all operations can be carried out.
Security lock is not engaged (default setting).
Security lock is not engaged (default setting).
1
Use the jog dial to move the cursor to REC CONTROL.
2
Turn the shuttle dial clockwise, and then use the jog dial
to select "ADMIN" or "USER".
This completes the setting.
3
Press the EXIT/OSD button.
The display returns to the normal screen.
EXIT/OSD
English
Details of operation
D
Security lock setting
1
At the normal monitoring screen, press and hold the
SUHTTLE HOLD button for approximately 3 seconds.
The LOCK indicator at the front panel illuminates and the
buzzer sounds. The security lock is then set.
SHUTTLE HOLD
2
Press any operating button to check the security lock.
The password entry screen appears.
The screen display disappears after 5 seconds.
REC/STOP
3
Use the jog dial and the shuttle dial to enter the
password, and then turn the shuttle dial clockwise once
more.
The LOCK indicator goes off and the display returns to the
normal screen.
Note: Enter the password (example: "123456AB") that was
entered as the Administrator or User password setting.
1
63
POWER
FULL
ALARM FULL
2
3
LOCK
LOCK
LOCK
LOCK
LOCK
LOCK
LOCK

Advertisement