Oce PlotWave 340 User Manual page 156

Hide thumbs Also See for PlotWave 340:
Table of Contents

Advertisement

Error messages when validation fails
Error code
4
5, 6, 7
8
9
10
11, 12
156
Chapter 3 - Define your Workflow with Océ Express WebTools
Possible Causes
Check if the hostname or IP address is correctly typed.
Check that remote host is up and running and connected to the
network.
Check that SMB or FTP protocol is enabled on remote host
Check that the customer network security policy (firewall/switch)
does not block FTP ports
For SMB destination:
- check that the security level is set to "Normal"
- check that remote host supports SMB1 protocol (error code:
7)
For FTP destination: check FTP server is using port 21
Check if the remote username and password are correct.
For SMB destination: Check the remote user name syntax :
- For a remote host user: <hostname>\<username>
or <ip_address>\<username>
- For a domain user : <domainname>\<username>
The remote destination server has reached the maximum number
of connections. Check with the System administrator or try again
later.
Check that the remote folder is correctly typed
Check that the remote folder exists on remote host
For SMB destination: check that the share is correctly typed or
the share exists on remote host
For FTP destination: check that the remote folder have "list"
permissions for remote user
Check that the remote user has "write" permission on the remote
share (for SMB) and on the remote folder (for SMB and FTP)
Check that the remote folder is not full (error code: 12)
SMB destination: check that the remote username is correctly
typed (may happen if "guest" account is enabled on the remote
host).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plotwave 360