USER PROGRAMS

The user programs allow the parameters of certain
functions to be set, changed, or cancelled as desired.
Setting the power save and auto clear time modes.
1. Press and hold down the light (
simultaneously for more than 5 seconds until all the
s
alarm indicators (
q ,
t
,
in the display.
2. Use the left copy quantity (
program number. The selected number will blink in the
left side of the display.
3. Press the print (
) key. The entered program number
will be steadily lit and the currently selected parameter
number for the program will blink on the right side of the
display.
Program No.
1
Auto clear time
2
Preheat mode
3
Auto power
shut-off timer
5 Auto power
shut-off mode
Factory default settings are indicated with an
asterisk (*).
4. Select the desired parameter using the right copy
quantity (
) key. The entered parameter number will
blink on the right of the display.
5. Press the print (
) key. The right-hand number in the
display will be steadily lit and the entered value will be
stored.
To change the setting or to set another mode,
>
press the clear (
to step 2.
{
6. Press the light (
) or dark ( ) key to return to the
normal copy mode.
GB-12
{
) and dark ( ) keys
p
) blink and "– –" appears
,
) key to select a user
Parameters
0 OFF
1 30 sec.
* 2 60 sec.
3 90 sec.
4 120 sec.
5 10 sec.
* 0 30 sec.
1 60 sec.
2 90 sec.
0 2 min.
* 1 5 min.
2 15 min.
3 30 min.
4 60 min.
5 120 min.
0 OFF
* 1 ON
) key. The copier will return
TONER CARTRIDGE
REPLACEMENT
Be sure to use only original spare parts and
supplies.
When the toner cartridge replacement required (
cator will light up, replacement of the toner cartridge will
be needed soon. Obtain a new cartridge. When the

toner cartridge replacement (

toner cartridge must be replaced before copying can be
resumed. Replace the toner cartridge by following the
procedure below.
During a long copy run of a dark original, the
ready (
) indicator may blink, the
light up, and the copier stop, even though
toner is left. The copier automatically reple-
nish the toner level for up to 2 minutes and
then the ready (
Press the print (
1. Open the side cover while pressing the side cover
open button.
Then, push gently on both sides of the front cover and
open it.
2. Push the toner cartridge lock release lever and pull the
toner cartridge out. Dispose of the old toner cartridge
in accordance with local regulations.
Toner cartridge lock
release lever
After removing the toner cartridge, do not
shake it or tap on it. Doing so may cause toner
to leak from the cartridge. Put the old cart-
ridge immediately in the bag contained in the
box of the new cartridge.
s
) indi-
s
) indicator blinks, the
s
indicator
) indicator will light up.
) key to restart copying.