Olivetti d-Copia 12 Copier Operation Manual page 17

Digital copier
Hide thumbs Also See for d-Copia 12:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
• Do not touch the surface of the photoconductive
drum (green portion) when removing the misfed
paper. Doing so may damage the drum and cause
smudges on copies.
• If the paper has been fed through the manual
bypass, do not remove the misfed paper through the
manual bypass. Toner on the paper may stain the
paper transport area, resulting in smudges on copies.
2. Close the side cover by pressing the round projections
near the side cover open button. The misfeed (
indicator will go out and the ready (
light up.
B. Misfeed in the fusing area
1. Lower the fusing unit release lever by rotating it all the
way.
Fusing unit
release lever
While you are lowering the fusing unit release lever, it
will not move smoothly at a location on the way.
However, be sure to lower the lever by rotating it all the
way to the location where it will not rotate as shown in
the illustration.
2. Gently remove the misfed paper from under the fusing
unit as shown in the illustration.
The fusing unit is hot. Do not touch the fusing unit
when removing misfed paper.
Do not touch the surface of the photoconductive
drum (green portion) of the drum cartridge when
removing the misfed paper. Doing so may damage
the drum and cause smudges on copies.
Do not remove the misfed paper from above the
fusing unit. Unfixed toner on the paper may stain
the paper transport area, resulting in smudges on
copies.
3. Raise the fusing unit release lever and then close the
side cover by pressing the round projections near the
side cover open button.
C. Misfeed in the transport area
1. Lower the fusing unit release lever by rotating it all the
way.
Fusing unit
release lever
)
t
) indicator will
While you are lowering the fusing unit release lever, it
will not move smoothly at a location on the way.
However, be sure to lower the lever by rotating it all the
way to the location where it will not rotate as shown in
the illustration.
2. Push gently on both sides of the front cover and
open it.
3. Rotate the feeding roller in the direction of the arrow
and gently remove the misfed paper from the exit area.
4. Raise the fusing unit release lever, close the front
cover and then close the side cover by pressing the
round projections near the side cover open button. The
misfeed (
indicator will light up.
When closing the covers, be sure to close the front
cover securely and then close the side cover. If
the covers are closed in the wrong order, the
covers may be damaged.
Feeding roller
) indicator will go out and the ready (
t
)
GB-15