3KH-2
Maintenance
item No.
Setting user data 1
U603
Description
Makes user settings to enable the use of the machine as a fax.
Purpose
To be run after installation of the facsimile kit if necessary.
Method
1. Press the start key. The port that is addressed by U698 is displayed when the optional dual FAX is
installed.
2. Press [LINE TYPE]. The current setting is displayed in reverse.
If the optional dual FAX has been installed and if U698 is set to [ALL] and settings for ports 1 and 2 are
not identical, the display is not highlighted.
3. Select the setting.
Display
DTMF
10
20
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting user data 2
U604
Description
Makes user settings to enable the use of the machine as a fax.
Purpose
Use this if the user wishes to adjust the number of rings that occur before the unit switches into fax receiving
mode when fax/telephone auto-select is enabled.
Method
1. Press the start key. The current setting is displayed.
2. Press [RINGS(F/T)#].
3. Change the setting using the +/- or numeric keys.
Description
Number of fax/telephone rings
If you set this to 0, the unit will start fax reception without any ringing.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Clearing data
U605
Description
Initializes data related to the fax transmission such as transmission history.
Purpose
To clear the transmission history.
Method
1. Press the start key. The port that is addressed by U698 is displayed when the optional dual FAX is
installed.
2. Press [CLEAR COM.REC.].
3. Press the start key. Initialization processing starts. When processing is finished, the screen for selecting
a maintenance item No. is displayed.
1-3-8
Description
Description
DTMF
10 PPS
20 PPS
Setting range
0 to 15
Service Manual
Initial setting
2 (120 V)/1 (220-240 V)
Y108810-2