2.11.1RESTARtiNG
If trying to restartthe enginewithin 10 seconds after it shutsdown,
the engine may NOT start. The system needs5 to 10 secondsto
reset.
If the engine is restarted after such a shutdown and the low oil
pressure has not been corrected, the engine will run for about 10
seconds as describedabove and then stop.
2.12 CHARGING THEBATTERY (XG700OE
&XGBOOOE)
Do not permit smoking, open flame, sparks or
any other source of heat around a battery. Wear
protective goggles, rubber apron and rubber
gloves when working
around a battery. Battery
electrolyte fluid is an extremely corrosive
sulfuric acid solution that can cause severe
burns. If spill occurs flush area with clear water
immediately.
Storage batteries
give off explosive
hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion.
Such an explosion
can shatter the battery and
cause blindness
or other serious injury.
Use batterycharger plug to keepthe battery chargedand ready
for use. Batterycharging should be done in a dry location.
1. Plug charger into "Battery ChargerInput"jack, located on the
control panel.Plug wall receptacleend of the battery charger
into a 120 Volt AC watt outlet.
2. Unplugbattery chargerfrom walt outlet and control paneljack
when generatoris going to be in use.
NOTE:
Do not use the battery chargerfor more than 48 hours at one
charge.
3.1 MAINTENANCE
SCHEDULE
Follow the calendar intervals. More frequent service is required
when operatingin adverseconditions noted below.
CheckOil Level
ChangeOil and Oil Filter:!:
CleanSparkArrestor Screen
Service Air Filter
ReplaceSpark Plug
$
"k
At Each Use
*Every Season/Every100 Hours
**Every Season/Every100 Hours
**Every Season/Every200 Hours
Every Season
Changeoil after first 30 hours of operation then every season.
Changeoil and oil filter every month when operating under heavy load or in
high temperatures.
Clean more often under dirty or dusty operating conditions. Replaceair filter
parts if very dirty.
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR S PECIFICATIONS
Model # ...................................................................... 005800, 005747
RatedMax. Power................................................................... 8.0 kW**
Surge Power................................................................................ 10 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 33.3 Amps**
Current @ 120V............................................................. 66.7 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
Model # ...................................................................... 005797, 005798
RatedMax. Power................................................................... 7.0 kW**
Surge Power............................................................................. 8.75 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 29.2 Amps**
Current @ 120V............................................................. 58.3 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
Model # .................................................................................... 005796
RatedMax. Power................................................................... 6.5 kW**
Surge Power............................................................................. 8.13 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 27.1 Amps**
Current @ 120V............................................................. 54.2 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
** Maximum wattage andcurrent a resubject t o, andlimitedby,suchfactors
asfuelBtucontent, a mbient t emperature, altitude, e ngine condition, e tc..
Maximum powerdecreases a bout 3 .5%for each1,000feetabove sealevel;
andwill alsodecrease a bout1%for each6° C (10° F)above16° C(60° F)
ambient t emperature.
3.2.2 ENGINE SPECIFICAtiONS
RatedHorsepower @ 3600 RPM.................................................... 14.5
Displacement............................................................................... 41Occ
Spark Plug Type................................... ChampionRC14YCor Equivalent
Spark Plug Part No.................................................................... 0E7585
Spark Plug Gap............................................... 0.030 inch or (0.76 ram)
GasolineCapacity............................................................ 9 U.S. gallons
Oil Type .................................... SeeChart in "Adding Engine Oil"Section
Oil Capacity ................................................ w/Filter Change = 1.5 Qts.
w/o FilterChange = 1.2 Qts.
Oil FilterPart No...................................................................... 070185B
Run Time/FuelConsumption-l/2 Load .. 10 Hours/ .73 gallons per hour
Class I1EmissionCertified
12