Generac Power Systems 005796-0 (XG6500) Owner's Manual

Xg series 6,500-8,000 watt portable generator
Hide thumbs Also See for 005796-0 (XG6500):
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

MODELS: 005796-0 (XG6500), 005797-0 (XG7000),
005798-0 (XG7000E), 005800-0 (XG8000),
005747-0 (XG8000E)
Owner's Manual
XG Series 6,500-8,000 Watt Portable Generator
Actoolsupply.com
Actoolsupply.com

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Generac Power Systems 005796-0 (XG6500)

  • Page 1 Actoolsupply.com MODELS: 005796-0 (XG6500), 005797-0 (XG7000), 005798-0 (XG7000E), 005800-0 (XG8000), 005747-0 (XG8000E) Owner's Manual XG Series 6,500-8,000 Watt Portable Generator Actoolsupply.com...
  • Page 2 Actoolsupply.com Generac XG10000E 5802 Portable Generator Generac XG4000 5778 Portable Generator Generac XG4000 5843 Portable Generator Generac XG4000 5844 Portable Generator Generac XG6500 5796 Portable Generator Generac XG7000E 5798 Portable Generator Generac XG7000E 5845 Portable Generator Generac XG8000E 5747 Portable Generator Generac XG8000E 5846 Portable Generator Generac XG8000E 5847 Portable Generator Actoolsupply.com...
  • Page 3: Table Of Contents

    Actoolsupply.com Table of Contents Introduction ............. 1 Maintenance ............11 Maintenance Schedule ..........11 Read this Manual Thoroughly ......... 1 Product Specifications ..........11 Safety Rules ............1 3.2.1 Generator Specifications ........11 Standards Index .............3 3.2.2 Engine Specifications ........12 3.2.3 Emissions Information ........12 General Information ..........
  • Page 4: Introduction

    Actoolsupply.com Introduction INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Indicates a hazardous situation or action which, if not Inc. This model is a compact, high performance, air-cooled, avoided, could result in minor or moderate injury. engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in NOTE: place of utility due to a power outage.
  • Page 5: Electrical Hazards

    Actoolsupply.com Safety Rules • Never use the generator or any of its parts as a step. Stepping ELECTRICAL HAZARDS on the unit can stress and break parts, and may result in • generator produces dangerously high voltage when in dangerous operating conditions from leaking exhaust gases, operation.
  • Page 6: Standards Index

    Actoolsupply.com Safety Rules • Do not insert objects through unit’s cooling slots. MODEL NO: • Do not operate the generator if connected electrical devices overheat, if electrical output is lost, if engine or generator sparks or if flames or smoke are observed while unit is running. SERIAL NO: •...
  • Page 7: General Information

    Actoolsupply.com General Information 1.1 UNPACKING • Refer to Figure 2 and install the wheel kit and frame foot as follows: • Remove all packaging material. • Slide the Axle Pin through the Wheel, Wheel S pacer (Washer) • Remove separate accessory box. and the Frame.
  • Page 8: Operation

    Actoolsupply.com Operation 2.1 KNOW THE GENERATOR Figure 3 – Generator Locations Read the entire Owner’s Manual and Safety Rules before operating this generator. Compare the generator to Figures 3 through 6 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.
  • Page 9: Battery Connection (Xg7000E & Xg8000E)

    Actoolsupply.com Operation 2.1.1 BATTERY CONNECTION (XG7000E & XG8000E) When the hour meter is in the Flash Alert mode, the maintenance message will always alternate with elapsed time in hours and NOTE: tenths. The hours will flash four times, then alternate with the maintenance message four times until the meter resets itself.
  • Page 10: How To Use The Generator

    Actoolsupply.com Operation 2.4 HOW TO USE THE GENERATOR Special Requirements There may be Federal or State Occupational Safety and Health If there are any problems operating the generator, please call the Administration (OSHA) regulations, local codes, or ordinances that generator helpline at 1-888-436-3722. apply to the intended use of the generator.
  • Page 11: Neutral To Frame Grounding

    Actoolsupply.com Operation 2.4.3 NEUTRAL TO FRAME GROUNDING • Add up the rated watts (or amps) of all loads to be connected at one time. This total should no be greater than (a) the rated If service work is performed on the alternator, DO NOT discard wattage/amperage capacity of the generator or (b) circuit the white jumper wires from the terminal block to the alternator breaker rating of the receptacle supplying the power.
  • Page 12: Before Starting The Generator

    Actoolsupply.com Operation Electric Nail Gun ........1200 TEMPERATURE IN DEGREES FAHRENHEIT ( F) Electric Range (per element) .
  • Page 13: To Start The Engine

    Actoolsupply.com Operation   Do not overfill the fuel tank. Always leave room for fuel Figure 10 – Fuel Shut-off Valve expansion. If the fuel tank is overfilled, fuel can overflow onto a hot engine and cause FIRE or EXPLOSION. Wipe up any spilled fuel immediately.
  • Page 14: Electric Starting (Xg7000E & Xg8000E)

    Actoolsupply.com Maintenance   2.8.1 ELECTRIC STARTING (XG7000E & XG8000E) Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will • To start the engine, press and hold the Start/Run/Stop switch in remain around the battery for a long time after the “Start”...
  • Page 15: Engine Specifications

    Actoolsupply.com Maintenance Model # ............... 005797-0, 005798-0 • Fuel System • Air Induction System Rated Max. Power ..............7.0 kW** Fuel Tank ~ Intake pipe/manifold Surge Power ................8.75 kW Fuel Cap ~ Air cleaner Rated AC Voltage ..............120/240 Ignition System Carburetor •...
  • Page 16: To Clean The Generator

    Actoolsupply.com Maintenance NOTE: • Coat gasket of new filter with clean engine oil. Turn filter DO NOT use a garden hose to clean generator. Water can clockwise until gasket contacts lightly with filter adapter. Then enter the engine fuel system and cause problems. In addition, tighten an additional 3/4 turn.
  • Page 17: Clean Spark Arrestor Screen

    Actoolsupply.com Maintenance Figure 13 – Air Filter 3.6 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepare it for storage.
  • Page 18: Other Storage Tips

    Actoolsupply.com Battery Service 3.8 OTHER STORAGE TIPS Figure 16 – Battery Removal • Do not store gasoline from one season to another. FUEL TANK • Replace any gasoline can that starts to rust. Rust and/or dirt in ASSEMBLY the gasoline will cause problems with the carburetor and fuel system.
  • Page 19: Troubleshooting

    Actoolsupply.com Troubleshooting 5.1 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine is running, but no AC output 1. Circuit breaker is open. 1. Reset circuit breaker. is available. 2. Poor connection or defective cord set. 2. Check and repair. 3. Connected device is bad. 3.
  • Page 20: Notes

    Actoolsupply.com Notes Actoolsupply.com...
  • Page 21: Warranty

    Actoolsupply.com Warranty CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board (CARB) and the United States Environmental Protection Agency (EPA), together with Generac Power Systems, Inc. (Generac), are pleased to explain the Emission Control System warranty on your new 2008 and later generator.
  • Page 22: Emission Control System Warranty

    Actoolsupply.com Warranty EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS warranty) for equipment using small spark-ignited engines: (a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter.
  • Page 23 Actoolsupply.com Warranty GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR XG SERIES PORTABLE GENERATORS For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its XG Series generators will be free from defects in materials and workmanship for the items and period set forth below.
  • Page 24: Manual Del Propietario

    Actoolsupply.com MODELO: 005796-0 (XG6500), 005797-0 (XG7000), 005798-0 (XG7000E), 005800-0 (XG8000), 005747-0 (XG8000E) Manual del propietario XG Series Generador portátil de 6,500-8,000 vatios GARANTÍA LIMITADA 2 AÑOS Actoolsupply.com...
  • Page 25 Actoolsupply.com Tabla de contenidos Introducción ............1 Mantenimiento ............11 Cronograma de mantenimiento ........11 Lea este manual completamente ......1 Especificaciones del producto ........11 Reglas de seguridad ..........1 3.2.1 Especificaciones del generador ......11 Índice de estándares ............3 3.2.2 Especificaciones del motor ......12 3.2.3 Información sobre emisiones ......12 Información General ..........
  • Page 26: Introducción

    Actoolsupply.com Instrucciones de seguridad importantes INTRODUCCIÓN CUIDADO Gracias por comprar este modelo de Generac Power Systems, Inc. Indica una situación peligrosa o acción que, si no se evita, puede Este modelo es un generador impulsado por motor, refrigerado por aire, traer como resultado un daño menor o moderado.
  • Page 27 Actoolsupply.com Instrucciones de seguridad importantes Guarde estas instrucciones – El fabricante sugiere que estas reglas para la operación segura se copien y publiquen cerca del sitio de instalación de la unidad. Debe insistirse en la seguridad para todos los operadores y potenciales operadores de este equipo •...
  • Page 28: Índice De Estándares

    Actoolsupply.com Instrucciones de seguridad importantes • Limpie cualquier derrame de combustible inmediatamente. Asegúrese de que no se haya dejado materiales combustibles sobre o cerca del MODELO NO: generador. Mantenga el área circundante del generador limpia y libre de residuos y conserve un espacio de cinco (5) pies a todos los lados SERIE NO: para permitir una ventilación apropiada del generador.
  • Page 29: Información General

    Actoolsupply.com Información General 1.1 DESEMPAQUE NOTA: El kit de ruedas no está diseñado para su uso en las pistas. • Retire todo el material de empaque. • Retire la caja separada de accesorios. • Consulte la figura 2 e instale el juego de rueda y la pata del •...
  • Page 30: Operación

    Actoolsupply.com Operación 2.1 CONOCIENDO EL GENERADOR 22. Arranque de culata – Use para arrancar el motor manualmente. Lea completamente el manual del propietario y las reglas de seguridad Figura 3 - Controles del generador antes de operar este generador. Compare el generador con las figuras de la 3 a la 5 para familiarizarse con las ubicaciones de los diversos controles y ajustes.
  • Page 31: Conexión De La Batería

    Actoolsupply.com Operación 2.1.1 CONEXIÓN DE LA BATERÍA Cuando el medidor de horas está en el modo de alerta de destello (Flash Alert), el mensaje de mantenimiento siempre alternara con el tiempo NOTA: transcurrido en horas y décimos. Las horas destellarán cuatro veces, La batería incluída en el generador ha sido cargada completamente.
  • Page 32: Cómo Usar Este Generador

    Actoolsupply.com Operación 2.4 CÓMO USAR ESTE GENERADOR Requerimientos especiales Puede haber regulaciones federales o estatales respecto a la salud y seguridad ocupacional (OSHA), códigos locales, u ordenanzas que se apliquen al uso que se quiera dar al generador. Nunca opere en áreas cerradas o interiores. NUNCA lo use en el hogar ni en áreas parcialmente Por favor consulte con un electricista calificado, inspector eléctrico o la encerradas como los garajes.
  • Page 33: Conexión A Tierra Del Neutro Al Marcos

    Actoolsupply.com Operación 2.4.3 CONEXIÓN A TIERRA DEL NEUTRO AL MARCOS 2.5 NO SOBRECARGUE EL GENERADOR Si se está dando servicio al alternador, NO descarte los cables del Sobrecargar un generador en exceso de su capacidad de potencia nominal jumper blanco del bloque terminal a la tierra del alternador, ubicada en puede traer como resultado daños al generador y a los dispositivos la portadora de cojinetes posterior.
  • Page 34: Antes De Arrancar El Generador

    Actoolsupply.com Operación Cortador de setos ............... 450 Herramienta de impacto .............. 500 Cualquier intento de arrancar el motor antes de que se le haya Plancha ..................1200 dado servicio apropiado con el aceite recomendado puede * Eyector ..................800 traer como resultado una falla del motor. Cortadora de césped ..............
  • Page 35: Arranque Del Motor

    Actoolsupply.com Operación Figura 9 - Tanque de combustible Figura 11 - Posición de Choke NO LLENAR más allá de esta separación 2.8.1 ARRANQUE MANUAL (RECULE) • Este generador también está equipado con un arrancador manual de recule que se puede usar si la batería está descargada. •...
  • Page 36: Sistema De Apagado Por Baja Presión De Aceite

    Actoolsupply.com Mantenimiento 2.10 SISTEMA DE APAGADO POR BAJA PRESIÓN 3.1 CRONOGRAMA DE MANTENIMIENTO DE ACEITE Siga los intervalos del calendario. Se requiere un servicio más frecuente cuando se opera en condiciones adversas como las que se indica abajo. El motor está equipado con un sensor de presión que apaga el motor en Revise el nivel de aceite en cada uso forma automática cuando la presión de aceite baja a menos de 5 psi.
  • Page 37: Especificaciones Del Motor

    Actoolsupply.com Mantenimiento 3.2.2 ESPECIFICACIONES DEL MOTOR 3.3 RECOMENDACIONES GENERALES Potencia nominal en caballos @ 3600 RPM ........14.5 La garantía del generador no cubre ítems que hayan sido objeto de abuso Desplazamiento................410cc o negligencia del operador. Para recibir el valor total de la garantía, el operador debe hacer el mantenimiento del generador tal como se instruye Tipo de bujías ........
  • Page 38: Revisar El Nivel De Aceite

    Actoolsupply.com Mantenimiento 3.3.4 REVISAR EL NIVEL DE ACEITE Figura 12 - Espaciamiento de la bujía Vea la sección “ANTES DE ARRANCAR EL GENERADOR” para mayor información sobre la revisión del nivel de aceite. El nivel de aceite debe revisarse antes de cada uso, o al menos cada ocho horas de operación. Siempre mantenga el nivel de aceite.
  • Page 39: General

    Actoolsupply.com Mantenimiento 3.7 ALMACENAMIENTO POR LARGO PLAZO Es importante evitar que se formen depósitos de goma en las partes  Si usa el generador sobre algun terreno cubierto de esenciales del sistema de combustible como el carburador, la manguera césped, arbustos o plantas, debe estar equipado de combustible o el tanque durante el almacenamiento.
  • Page 40: Servicio A La Batería

    Actoolsupply.com Servicio a la bateria 4.1 REEMPLAZO DE LA BATERÍA (XG7000E & XG8000E) Para reemplazar la batería (ver figura 16) • Retire el panel lateral como se muestra. Retire los cuatro pernos que aseguran el tanque de combustible. • Gire la válvula de combustible sobre el panel de control a la posición "OFF".
  • Page 41: Detección De Problemas

    Actoolsupply.com Detección de problemas 5.1 GUÍA DE DETECCIÓN DE PROBLEMAS PROBLEMA CAUSA CORRECCIÓN El motor está funcionando, pero no 1. El interruptor de circuito está abierto. 1. Reinicie el interruptor de circuito. hay salida de AC disponible. 2. Pobre conexión o cable defectuoso. 2.
  • Page 42: Notas

    Actoolsupply.com Notas Actoolsupply.com...
  • Page 43: Garantía

    Actoolsupply.com Garantía DECLARACIÓN DE GARANTÍA DE CONTROL DE EMISIONES FEDERAL Y DE CALIFORNIA SUS DERECHOS Y OBLIGACIONES DE GARANTÍA El directorio de recursos de aire de California (CARB) y la Agencia de protección ambiental de los Estados Unidos (EPA) junto con Generac Power Systems, Inc.
  • Page 44 Actoolsupply.com Garantía GARANTÍA DEL SISTEMA DE CONTROL DE EMISIONES Garantía de sistema de control de emisiones (garantía ECS) para equipo que usa motores pequeños de chispa. (a) Aplicabilidad: Esta garantía se aplica a equipo que utiliza motores pequeños para fuera de pista. El periodo de garantía ECS empezará...
  • Page 45 Actoolsupply.com Garantía GARANTÍA LIMITADA DE “DOS AÑOS” DE SISTEMAS DE POTENCIA GENERAC PARA GENERADORES PORTÁTILES SERIE XG Por un periodo de dos años desde la fecha de la venta original, Generac Power Systems, Inc. (Generac) garantiza sus generadores serie XG como libres de defectos en materiales y mano de obra por los ítems y periodos indicados abajo.

Table of Contents