Magnum DS50 / DS60s Dual Speed Hubs
Table 3.2c: Maximum segment lengths for common network configurations
Number
Repeater
of Hubs
Hop Count
1
1
2
2
2
2
2
2
3+
3
3.3

Powering the Magnum DS50 / DS60

Magnum DS50 / DS60 Dual-speed
Hub Plus incorporates an internal universal
power supply and has a recessed male IEC
connector for the AC power cord at the right-
rear. A six-foot 115vac 60Hz power cord is
supplied with each unit shipped within the United States and Canada.
Each DS50 / DS60 auto-ranging power supply supports installation environments where
the AC voltage is from 100 to 240 volts with an input frequency between 47 and 63 Hz, and
consumes a maximum of 20 watts.
In order to power down the unit, simply unplug either end of the power cable.
NOTE: The DC Power Supply option, -48VDC and 24VDC are described in APPENDIX B.
www GarrettCom com
.
Max. User
Segment
Repeater (Cascade)
Lengths (m)
100.0
100.0
92.0
79.5
60.0
.
Installation and User Guide (06/02)
Max. Inter-
Length (m)
N/A.
All ports TX
5.0
All ports TX
20.0
All ports TX
1.0
1 hub T4, 1 hub TX and T4
(class I repeater), all cables
Cat. 5
1.0
All ports TX
AC Power: Auto-ranging
100-240 vac, 47-63 Hz
25
Notes

Advertisement