TROUBLESHOOTING
1. Make sure the Power LED (L1 and/or L2) is ON.
2. Make sure the Voltage is within specifications (18-32V@1A).
3. Make sure the fiber ports and TX ports are properly connected.
4. Verify that Port LED's are ON for connected ports.
5. Verify the status of the fault (RM) LED.
6. Verify cabling (pin-outs & integrity).
7. Verify that cabling is Category 5 (or higher) for 100Mbit TX
Operation, 62.5/125 µm @1300nm for 100 Mbit FX Operation.
8. Verify TX port#7 is connected to RX port#8 (and vice versa).
9. Verify that only one 608 switch is in RM (redundancy manager)
mode.
SUPPORT
FCC STATEMENT
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
(1) This device may not cause harmful Interference
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Contact N-TRON Corp. at:
TEL: 251-666-9878
FAX: 251-666-9833
info@n-tron.com
www.n-tron.com
18