Power Supply Troubleshooting; Procedure 1 Power Status Check; Procedure 1 - Toshiba Tecra A2-S316 Maintenance Manual

Maintenance manual
Hide thumbs Also See for Tecra A2-S316:
Table of Contents

Advertisement

2 Troubleshooting Procedures
2.3

Power Supply Troubleshooting

The power supply controller controls many functions and components. To determine if the
power supply is functioning properly, start with Procedure 1 and continue with the other
Procedures as instructed. The procedures described in this section are:
Procedure 1: Power Status Check
Procedure 2: Error Code Check
Procedure 3: Connection Check
Procedure 4: Charging Check
Procedure 5: Replacement Check

Procedure 1

Power Status Check
The following icons indicate the power supply status:
q Battery icon
q DC IN icon
The power supply controller displays the power supply status with the Battery icon and the
DC IN icon as listed in the tables below.
Battery icon
Lights orange
Lights green
Blinks orange
(even intervals)
Doesn't light
2-6
Table 2-1 Battery icon
Battery is charged and the external DC is input. It has no relation with
ON/OFF of the system power.
Battery is fully charged and the external DC is input. It has no relation
with ON/OFF of the system power.
The battery level is low while the system power is ON.
Any condition other than those above.