3-Wire Connection: Power Supply Cord; 3-Wire Connection: Direct Wire - Kenmore HE 4 Electric dryer 110.8508 Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

3. Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
C
.........
F
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4"(1.9 cm) UL listed strain relief
D. Center silver-colored
terminal block screw
E. Neutral wire (white or center wire)
F Neutral grounding
wire (green with yellow stripes)
4.
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
5. Tighten strain relief screw.
6.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection.
Now, go to
"Venting Requirements."
3-wire connection:
Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
D
E
A. 3-wire receptacle
(NEMA type 10-30R)
B. 3-wire plug
C. Ground prong
D. Spade terminals with up turned ends
E. _" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
G
F
1. Loosen or remove center silver-colored
terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored
terminal screw of the
terminal block. Tighten screw.
C
A
...............
_1
B
..............................................
............................. D
____ i_
_............................................................
E
A. Externalground conductor screw
B. Neutral grounding wire (green with yellow stripes)
C. Center silver-colored terminal block screw
D. Neutral wire (white er center wire)
E. _" (1.9 cm) UL listed strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection.
Now, go to
"Venting Requirements."
3-wire connection:
Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2 '' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
<
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
12