4-Wire Connection: Direct Wire; Venting Requirements - Kenmore HE 4 Electric dryer 110.8508 Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

1=
2.
Remove center silver-colored
terminal block screw.
Remove neutral grounding
wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire and the neutral wire (white or center wire) of
power supply cord under center, silver-colored
terminal block
screw. Tighten screw.
4-wire connection:
Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2 '' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
A. External ground conductor
screw - Dotted line shows
position of NEUTRAL grounding
wire before being moved to
center silver-colored
terminal block screw
B. Center silver-colored
terminal block screw
C. Neutral grounding
wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. 3/_,, ( 1.9 cm) UL listed strain relief
Connect ground wire (green or bare) of power supply cord to
external ground conductor
screw. Tighten screw.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1=
2.
Remove center silver-colored
terminal block screw.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire and place the hooked end (hook facing right)
of the neutral wire (white or center wire) of direct wire cable
under the center screw of the terminal block. Squeeze
hooked ends together. Tighten screw.
A
_
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. _" (1.9 cm) UL listed strain relief
D. Center silver-colored
terminal block screw
E. Neutral wire (white or center wire)
F. Neutral grounding
wire (green with yeflow stripes)
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection.
Now, go to
"Venting Requirements."
E
A. External ground conductor
screw - Dotted line shows
position of NEUTRAL grounding
wire before being moved
to center silver-colored
terminal block screw
B. Center silver-colored
terminal block screw
C. Neutral grounding
wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief
11