27 in. (69 cm) electric dryer

Advertisement

Available languages

Available languages

Quick Links

27 IN. (69 CM) ELECTRIC DRYER
INSTALLATION INSTRUCTIONS
INSTRUCCIONES
DE INSTALACION PARA LA
SECADORA ELECTRICA DE 27 PULG. (69 CM)
Table of Contents / Indice
DRYER SAFETY ...........................................................
1
INSTALLATION
INSTRUCTIONS
...............................
2
Tools and Parts .........................................................
2
Location Requirements
...........................................
2
Electrical Requirements ............................................
3
Electrical Connection ................................................
4
Venting Requirements
..............................................
8
Plan Vent System ......................................................
8
Install Vent System .................................................
10
Install Leveling Legs ...............................................
10
Level Dryer ..............................................................
11
Connect Vent ..........................................................
11
Complete Installation ..............................................
11
SERVICE NUMBERS ............................. BACK COVER
SEGURIDAD
DE LA SECADORA ............................ 12
INSTRUCCIONES
DE INSTALACION ..................... 12
Herramientas y piezas ...........................................
t2
Requisites de lecalizaci6n ....................................
t2
Requisites el6ctricos .............................................
t3
Cenexi6n el6ctrica .................................................
15
Requisites de ventilaci6n .......................................
t9
Planificacion del sistema de ventilacion ............... 20
Instalaci6n del sistema de ventilacion ................... 22
Instalacion de las patas niveladoras ..................... 22
Nivelacion de la secadora .....................................
23
Conexion del ducto de escape ............................. 23
Complete la instalacion .........................................
23
NUMEROS DE SERVICIO ........... CONTRAPORTADA
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided
many important
safety
messages
in this manual
and on your appliance.
Always
read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
3979976

Advertisement

loading

Summary of Contents for Kenmore 6962 - 600 7.0 cu. Ft. Capacity Electric Dryer

  • Page 1 27 IN. (69 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION PARA LA SECADORA ELECTRICA DE 27 PULG. (69 CM) Table of Contents / Indice DRYER SAFETY ............SEGURIDAD DE LA SECADORA ......12 INSTALLATION INSTRUCTIONS ....... INSTRUCCIONES DE INSTALACION ..... 12 Tools and Parts ............
  • Page 2 INSTALLATION INSTRUCTIONS A grounded electrical outlet located within 2 ft (61 cm) of • either side of the dryer. See "Electrical Requirements." • A sturdy floor to support the total weight (dryer and load) of Check that you have everything necessary for correct installation. 200 Ib (90.7 kg).
  • Page 3 • Companion appliance spacing s hould a lso beconsidered. If using a power supply cord: Use a UL approved power supply cord kit marked for use with clothes dryers. The kit should contain: 14" max (76 cm) • A UL approved 30 amp power supply cord, rated 120/240 volt _'_49"...
  • Page 4 Power S upply Cord Direct W ire Fire Hazard Use t0 gauge somid copper wire, Use a UL approved strain retief, Disconnect power before making emectdcamconnections. Connect neutral wire (white or center wire) to center terminal (simver). Ground wire (green or bare wire) must be connected green ground connector, Connect remaining 2 suppmy wires to remaining...
  • Page 5 1. Remove center terminal block screw. Electrical Connection Options 2. Remove appliance ground wire (green with yellow stripes) If your home has: And you will be Go to Section: from external ground connector screw. Fasten it under center, connecting to: silver-colored terminal block screw.
  • Page 6 Connect ground wire (green or bare) of power supply cable to 4-wire connection: Direct Wire external ground conductor screw. Tighten screw. Place the hooked end of the neutral wire (white or center wire) IMPORTANT: A 4-wire connection is required for mobile homes of power supply cable under the center screw of terminal and where local codes do not permit the use of 3 wire block (hook facing right).
  • Page 7 Loosen or remove center terminal block screw. Loosen or remove center terminal block screw. Connect neutral wire (white or center wire) of power supply Place the hooked end of the neutral wire (white or center wire) cord to the center, silver-colored terminal screw of the of power supply cable under the center screw of terminal terminal block.
  • Page 8 4. Tighten strain relief screws. • The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
  • Page 9 NOTE: The following kits for close clearance alternate Optional exhaust installations installations are available for purchase. Call 1-800-4-MY-HOME ® This dryer can be converted to exhaust out the right side, left (1-800-469-4663). side, or through the bottom. • Over-The-Top Installation: Part Number 26-49900 Periscope Installation (For use with dryer vent to wall vent mismatch):...
  • Page 10 Recommended hood styles areshown h ere. 1. (Optional) Put on safety glasses and gloves. 2. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 3. Connect vent to exhaust hood. Vent must fit inside exhaust hood.
  • Page 11 0o ' sl:sleS J? tnsts//sl: on Check the levelness of the dryer. Check levelness first 1. Check to be sure all parts are now installed. If there is an side-to-side, then front-to-back. extra part, go back through the steps to see which step was skipped.
  • Page 12 INSTRUCCIONES DE INSTALACION PARA LA SECADORA ELECTRICA DE 27 PULG. (69 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demas es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual yen su electrodomestico. Lea y obedezca siempre todos los mensajes de seguridad= Este sfmbolo le llama la atencion sobre peligros potenciales que pueden ocasionar la muerte o una lesion a...
  • Page 13 • Un contacto con conexi6n a tierra ubicado a unos 2 pies Tambien se debe considerar espacio adicional para otro (61 cm) de cualquiera de los lados de la secadora. Vea electrodomestico que le acompa_e. "Requisitos electricos". • Un piso resistente para soportar la secadora con un peso (76 cm) total (secadora y carga) de 200 Ibs (90,7 kgs).
  • Page 14 Conexibn el_ctrica Si el contacto de pared luce como _ste: Para instalar su secadora adecuadamente, usted debe determinar el tipo de conexi6n electrica que va a usar y seguir las instrucciones que aquf se proveen para el caso. • Si los c6digos locales no permiten la conexi6n de un conector para conexi6n a tierra del equipo al alambre neutro, yea "Conexi6n opcional de 3 hilos".
  • Page 15 Cable de suministm eI_ctrico Cableado directo Pemigre de Incendio PeHgro de Incendio Uti_iee alambres de cobre s6_ido de ancho 10° Use un cabte de suministro emectrice nuevo de 30 amperes con aprobacion Use un protector de cables con aprobaci@_ UL. Use un protector de cables con aprobacion Desconecte...
  • Page 16 Opciones para la conexi6n el_ctrica Saque el tornillo central del bloque de terminal. Saque el hilo de tierra del aparato (verde con rayas amarillas) Si su casa tiene: Y usted va a Vaya a la del tornillo conector de tierra externo. Fijelo debajo del conectar con: secci6n:...
  • Page 17 Conecte el hilo de tierra (verde o desnudo) del cable de Conexi6n de 4 hilos: Cable directo suministro electrico al tornillo del conductor de tierra externo. Apriete el tornillo. IMPORTANTE: Se necesita una conexi6n de alambre de cuatro Coloque el extreme del hilo neutro en forma de gancho (hilo hilos para las casas rodantes y para los casos en que los c6digos blanco o central) del cable de suministro electrico debajo del locales no permitan el use de conexiones...
  • Page 18 Conexibn de 3 hilos: Cordbn de suministro el6ctrico Conexibn de 3 hilos: Cable directo Use cuando los c6digos locales permitan la conexi6n del Use cuando los cbdigos locales permitan la conexi6n del conductor de tierra del gabinete al hilo neutro. conductor de tierra del gabinete al hilo neutro.
  • Page 19 Coloque los extremos enganchados de los otros hilos del 6. Conecte un hilo de tierra de cobre separado desde el tornillo conector de tierra externo a tierra adecuada. cable de suministro electrico debajo de los tornillos exteriores del bloque de terminal (con los ganchos mirando hacia la derecha).
  • Page 20 • La salida de la secadora no debe conectarse en ningOn ducto de escape de gas, chimenea, pared, techo o el espacio oculto de un edificio. • No use una capota de ventilaci6n con pestillo magnetico. • No instale el ducto de escape de metal flexible en paredes, Instalaciones tipicas de escape techos o pisos encerrados.
  • Page 21 Previsiones especiales para las instalaciones en casas rodantes El ducto de escape debera sujetarse firmemente en un lugar no inflamable de la estructura de la casa rodante y no debe terminar debajo de la casa rodante. El ducto de escape debe terminar en el exterior.
  • Page 22 El estilo de capota de ventilaci6n angular (que se ilustra a continuaci6n) es aceptable. 1. (Opcional) P6ngase lentes de seguridad y guantes. 2. Instale la capota de ventilaci6n. Emplee una masilla de calafateo para sellar la abertura de la pared externa alrededor de la capota de ventilaci6n.
  • Page 23 Revise la nivelaci6n de la secadora. Verifique primero de lado a 1. Revise para cerciorarse de que todas las piezas esten lade y luego del frente hacia atras. instaladas. Si hay alguna pieza extra, vuelva a revisar todos los pasos para ver cual se omiti6. 2.
  • Page 24 Your Home ..For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances ancl items like garage door openers and water heaters.