Kenmore 6965 - 600 5.9 cu. Ft. Capacity Electric Flatback Dryer Installation Instructions Manual

Kenmore 6965 - 600 5.9 cu. Ft. Capacity Electric Flatback Dryer Installation Instructions Manual

29" (73.7cm) electric dryer
Hide thumbs Also See for 6965 - 600 5.9 cu. Ft. Capacity Electric Flatback Dryer:
Table of Contents

Advertisement

Available languages

Available languages

29" (73.7CM) ELECTRIC DRYER
INSTALLATIONINSTRUCTIONS
INSTRUCCIONES DE INSTALACION PARA
LASECADORA ELI_CTRICADE 29" (73.7 CM)
Table ofContents
DRYER SAFETY ....................................... 1
Tools and Parts...................................... 3
Location Requirements
........................ 3
Electrical Requirements ......................... 4
Electrical Connection ............................. 6
Venting Requirements ......................... 11
Plan Vent System ................................ 12
Install Vent System .............................. 13
Install Leveling Legs ............................ 13
Connect Vent ....................................... 13
Level Dryer ........................................... 14
Reverse Door Swing (Optional) ........... 14
Complete Installation ........................... 15
SERVICE NUMBERS ....... BACK COVER
indice
Herramientas y piezas ......................... 17
Requisitos de ubicaci6n ...................... 18
Requisitos electricos ........................... 19
Conexi6n electrica ............................... 21
Requisitos de ventilaci6n .................... 26
Planificaci6n del sistema de
ventilaci6n ............................................ 28
Instalaci6n del sistema de
ventilaci6n ............................................ 29
Instalaci6n de las patas niveladoras ...29
Conexi6n del ducto de escape ........... 29
Nivelaci6n de la secadora ................... 29
C6mo invertir el cierre de
la puerta (opcional) .............................. 30
Complete la instalaci6n ....................... 31
NUMEROS DE
SERVlCIO ................. CONTRAPORTADA
DRYER SAFETY
Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8576655B

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 6965 - 600 5.9 cu. Ft. Capacity Electric Flatback Dryer

  • Page 1: Table Of Contents

    29" (73.7CM) ELECTRIC DRYER INSTALLATIONINSTRUCTIONS INSTRUCCIONES DE INSTALACION PARA LASECADORA ELI_CTRICADE 29" (73.7 CM) indice Table ofContents DRYER SAFETY ........1 SEGURIDAD DE LA SECADORA ..16 INSTALLATION INSTRUCTIONS .... 3 INSTRUCCIONES DE INSTALACION ..17 Tools and Parts........3 Herramientas y piezas ......17 Location Requirements ......
  • Page 2 " "Risk of Fire" Clothes dryer installation must be performed by a qualified installer. Install the clothes dryer according to the manufacturer's instructions and local codes. Do not install a clothes dryer with flexible plastic venting materials or flexible metal {foil type) duct.
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Flat-blade screwdriver Tin snips (newvent • installations) #2 Phillips screwdriver Level • Adjustable wrench that opens to 1" (25 mm) or Vent clamps •...
  • Page 4: Electrical Connection

    Dryer Dimensions Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. Mobile home installations require: • Metal exhaust system hardware, which is available for purchase from your dealer.
  • Page 5 If using a power supply cord: • At least 5 ft (1.52 m) long. Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: GROUNDING INSTRUCTIONS • A UL listed 30-amp power supply cord, rated [] For a grounded, cord-connected dryer: 120/240 volt minimum.
  • Page 6 Direct Wire Power Supply Cord Fire Hazard Fire Hazard Use a new UL listed 30 amp power supply cord. Use 10 gauge copper wire. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections. Disconnect power before making electrical connections.
  • Page 7: Complete Installation

    Style 2:Direct w irestrainrelief Electrical Connection Options • Unscrew the removable conduit connector and any If your home has: And you will be Go to Section screws from a 3/4" (19 mm) UL listed strain relief (UL connecting to: marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening.
  • Page 8 Remove neutral ground wire from external ground conductor 4-wire connection: Direct Wire screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, terminal block screw. Tighten screw. IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
  • Page 9 Connect ground wire (green or bare) of power supply cable 3-wire connection: Power Supply Cord to external ground conductor screw. Tighten screw. Use where local codes permit connecting cabinet-ground conductor to neutral wire: A ....A. 3-wire receptacle (NEMA type 10-301:?) B.
  • Page 10 Place the hooked ends of the other power supply cable wires 3-wire connection: Direct Wire under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
  • Page 11 4. Tighten strain relief screws. Rigid metal vent 5. Insert tab of terminal block cover into slot of dryer rear panel. • For best drying performance, rigid metal vents are Secure cover with hold-down screw. recommended. 6. Connect a separate copper ground wire from the external •...
  • Page 12 Exhaust Standard exhaust installation with rigid metal or flexible metal vent Recommended hood styles areshown h ere. (102 ram) (102 mm) A. Louvered hood style Alternate installations for close clearances B. Box hood style Venting systems come in many varieties. Select the type best The angled hood style (shown here) is acceptable.
  • Page 13: Plan Vent System

    Determine vent path • Select the route that will provide the straightest and most direct path outdoors. • Plan the installation to use the fewest number of elbows and turns. Excessive Weight Hazard • When using elbows or making turns, allow as much room Use two or more people to move and install dryer, as possible.
  • Page 14 Reversible Super Wide Side-Swing Door Check t helevelness ofthedryer. Check l evelness first s ide to side, t henfront t oback. Ifthedryer i snotlevel, prop upthedryer u sing awood block. Use awrench t oadjust thelegs upordown andcheck again forlevelness. 1. Place towel (A) on top of dryer to avoid damaging surface. 2.
  • Page 15: Level Dryer

    10. Remove door strike plug (B). Insert the door strike you Wipe dryer drum interior thoroughly with a damp cloth to removed in Step 8 into hole and secure with screw. Insert remove any dust. door strike plug into original door strike hole and secure Select a Timed Dry heated cycle, and start the dryer.
  • Page 16: Seguridad De La Secadora

    INSTRUCCIONES DE INSTALACION PARA LASECADORA ELI CTRICA DE 29" (73,7 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los dem&s es muy importante, Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodom6stico. Lea y obedezca siempre todos los mensajes de seguridad.
  • Page 17: Instrucciones De Instalacion

    INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENClA: A fin de reducir el riesgo de incendio, descarga el6ctrica o de daSo alas personas que usen la secadora, deben seguirse las precauciones bAsicas, incluidas las siguientes: Lea todas las instrucciones antes de usar la secadora. No repare o reemplace ninguna pieza de la secadora ni trate de reparada a menos que esto se recomiende No coloque los objetos expuestos...
  • Page 18: Requisitos Electricos

    Dimensiones de la secadora 43A"' ..22 _/4" 433/_. (1102 mm) ..(1102 m_) *26" '273/4" '_ _ L >__ 186o (7os _ )% _ ....:lJ 29 ..'¢' (737 ram} (737 ram) Peligro de Explosi6n Mantenga los matedales y vapores inflamables, corno la gasolina, lejos de la secadora.
  • Page 19: Conexi6N Electrica

    Tambien sedebe considerar espacio a dicional para otro Proveer el suministro electrico requerido de 3 6 4 alambres, electrodomestico queleacompaffe. monofasico, de 120/240 voltios, 60 Hz, CA solamente (o un suministro electrico de 3 6 4 alambres, de 120/208 voltios, _._ 3"* si se especifica en la placa indicadora de corriente/de (76 ram)
  • Page 20 Si el contacto de pared luce come _ste: • Por Io menos 5 pies (1,52 m) de largo. INSTRUCCIONES PARA LA CONEXION A TIERRA [] Para la conexi6n de una secadora mediante cable el6ctrico conectado a tierra: Esta secadora debe estar conectada a tierra. En el caso de Contacto de 4 alambres (14-30R) funcionamiento defectuoso o averia, la conexi6n a tierra...
  • Page 21 Cable de suministro el_ctrico Cable directo Peligro de IncendJo Peligro de Incendio Use un cable de suministro el6ctrico nuevo de Utilice aiambres de cobre s61ido de ancho 10. 30 amperes que est_ en la |ista de UL. Use un protector de cables que est_ en la lista de UL. Use un protector de cabmes que est_ en la lista de UL.
  • Page 22 Haga pasar el cable de suministro de energia a traves Opciones para la conexibn el_ctrica del protector de cables. AsegQrese de que el aislamiento de cables del cable de suministro de energia este dentro Si su casa tiene: Y usted va a Vaya a la seccibn del protector de cables.
  • Page 23 Saque el hilo de tierra neutro del tornillo conductor de tierra 6. Introduzca la lengQeta de la cubierta del bloque de terminal externo. Conecte el hilo neutro de puesta a tierra y el hilo en la ranura del panel posterior de la secadora. Asegure neutro (hilo blanco o central) del cable de suministro de la cubierta con el tornillo de sujeci6n.
  • Page 24: Requisitos De Ventilaci6N

    Saque el hilo de tierra neutro del tornillo conductor de tierra Coloque los extremos en forma de gancho de los otros hilos externo. Conecte el hilo neutro de puesta a tierra y coloque del cable de suministro electrico debajo de los tornillos el extremo en forma de gancho (gancho mirando hacia exteriores del bloque de terminal (con los ganchos mirando la derecha) del hilo neutro (blanco o central) del cable de...
  • Page 25 Conecte los otros hilos a los tornillos exteriores del bloque de Coloque el extremo en forma de gancho del hilo neutro (hilo terminal. Apriete los tornillos. blanco o central) del cable de suministro el6ctrico debajo del tornillo central del bloque de terminal (con el gancho mirando hacia la derecha).
  • Page 26 Conexi6n opciona{ d e 3 hilos Use para cable directo o cable de suministro el6ctrico donde los c6digos locales no permitan la conexi6n del conductor de tierra del gabinete con el hilo neutro. 1. Saque el tornillo central del bloque de terminal. Saque el hilo de tierra neutro del tornillo conductor de tierra externo.
  • Page 27 Ventilacibn Ducto de escape de metal rigido • Para un 6ptimo rendimiento de secado, se recomiendan Los estilos recomendados de capotas de ventilaci6n se ductos de escape de metal rfgido. ilustran aqui. • Se recomienda el ducto de escape de metal rfgido para evitar que se aplaste o se tuerza.
  • Page 28 Instalaci6n en la parte superior: Pieza nOmero 26-49900 Instalaci6n de periscopio (Para usar si hay desacoplo entre el ducto de escape de la secadora y el ducto de escape de la pared): Seleccione su tipo de instalaci6n de ventilaci6n Pieza nOmero 26-49901 - Desacoplo de menos de 5"...
  • Page 29: Ventilaci6N

    Cuadro del sistema de ventilaci6n Examine las patas niveladoras. Localice la marca en forma de diamante. No. de Tipo de Capotas de Capotas vueltas ducto ventilacibn de angulares de 90 ° caja o tipo persianas codos Atornille con la mano las patas en los orificios de las patas. Metal rigido 64 pies (20 m) 58 pies (17,7 m)
  • Page 30 Puerta super ancha de abertura lateral de posici6n reversible (opt o Si Io desea, puede cambiar la direcci6n del cierre de la puerta del lado derecho al lado izquierdo....Puerta grande de abertura lateral de posici6n reversible 1. Coloque una toalla (A) encima de la secadora evitar da_os en la superficie.
  • Page 31 Introduzca los tornillos en los orificios inferiores en el lado 7. Quite la pelicula protectora azul que esta en la consola y izquierdo de la carcasa. Atornillelos por la mitad. Coloque la cinta adhesiva que haya quedado en la secadora. la puerta de tal forma que el extremo grande de la ranura de 8.
  • Page 32 Your Home For troubleshooting, product manuals and expert advice: managemylife www.managemylife.com For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself.

This manual is also suitable for:

11067741600110.69422801

Table of Contents