Panasonic VB-9411ADSUK Operation Instructions Manual page 126

Table of Contents

Advertisement

PROGRAMMING (MODE 1)
0501#-(0 or 1)#
MULTI-PURPOSE RELAY 2 FUNCTION
Sets which function is used to operate relay 2 on VB-
9273UK (Doorphone/Doorlatch I/F Card).
Sets whether to use relay 2 for control of door opener B,
or to use relay 2 for control of the External Ringer.
0#: Control of door opener B
1#: Control of external ringer
REFERENCE : See External Ringer control in MODE 2 (01-
04)11#.
0502#-(0 or 1)#
MULTI-PURPOSE RELAY 1 OPERA-
TION
Sets the time that relay 1 on VB-9273UK (Doorphone/
Doorlatch I/F Card) operates.
0#: Relay operated as programmed time
1#: Relay operated continually
REFERENCE : See operating time in MODE 1 0504#.
0503#-(0 or 1)#
MULTI-PURPOSE RELAY 2 OPERA-
TION
Sets the time that relay 2 on VB-9273UK (Doorphone/
Doorlatch I/F Card) operates.
0#: Relay operated as programmed time
1#: Relay operated continually
REFERENCE : See operating time in MODE 1 0505#.
0504#-(0, 1-7)#
MULTI-PURPOSE RELAY 1 OPERA-
TION TIMER
Sets the control time when "0# Relay operated as
programmed time" is set at MODE 1, address 0502#-(0
or 1).
0#: 0.125 second
1#: 1 second
2#: 2 seconds
3#: 3 seconds
REFERENCE : See Relay 1 in MODE1 0502#.
4#: 4 seconds
5#: 5 seconds
6#: 6 seconds
7#: 7 seconds
P-32
0505#-(0, 1-7)#
MULTI-PURPOSE RELAY 2 OPERA-
TION TIMER
Sets the control time when "0# Relay operated as
programmed time" is set at MODE 1, address 0503#-(0
or 1).
0#: 0.125 second
1#: 1 second
2#: 2 seconds
3#: 3 seconds
REFERENCE : See MODE 1 0503#.
0601#-(0 or 1)#
TRUNK TO TRUNK
By pressing the
MEMORY
Exchange line on hold and another Exchange line on
talk are connected together.
This function also applies to conference calls that have
been connected through the Direct Inward System
Access (DISA).
0#: Disable
1#: Enable
0602#-(0, 1 or 2)#
TRUNK TO TRUNK END TYPE
The following are ways to cut off the connection of a
trunk-to-trunk call.
a) Detects end of call (break signal) on Exchange
line and ends call.
b) Ends call after a specified time period elapses
after connection is made (timer).
c) Ends call using a combination of above two
methods.
0#: End by call detection (Do not use)
1#: Timer
2#: End by call detection or timer
4#: 4 seconds
5#: 5 seconds
6#: 6 seconds
7#: 7 seconds
5
REDIAL
, an