Windsor Chariot iScrub CSX24 Operating Instructions Manual page 43

Hide thumbs Also See for Chariot iScrub CSX24:
Table of Contents

Advertisement

1. SOLUTION STRAINER-COARSE
Located in bottom of tank. The coarse strainer protects
the finer strainer from large debris. If the fine strainer is
clean and the pump and solenoid valve are not
working, then check the coarse strainer for debris.
Drain the solution tank and clean the coarse strainer.
To remove the strainer, rotate the strainer counterclock-
wise. Cleanout the debris from wire mesh and re-
assemble.
2. SOLUTION STRAINER (FINE) AND SHUT-OFF
VALVE
The fine strainer is located in front left corner of
machine on disk models and in right rear corner of
cylindrical models. The fine strainer protects the pump
and solenoid valve from debris. If there is little or no
solution flow to the ground, first check to make sue the
shut-off valve is open. Next, check the strainer for
debris. To remove the strainer, first turn the shut-off
valve to the off position. Then, turn the bottom part of
the strainer counterclockwise until the bottom is sepa-
rated. Clean out the debris from the wire mesh and re-
assemble. Make sure the O-ring gasket is in place
when re-assembled. To resume flow, turn the shut-off
valve to the open position.
3. PUMP
The pump is located under the tank on the right side of
machine. The pump delivers solution from the tank to
the scrub deck.
To repair or replace pump:
1. Remove scrub deck skirts, Aqua-Mizer, and
squeegee from machine.
2. Lower scrub deck to gain access to pump
mounting plate.
3. Remove screw that secures pump mounting plate
to frame.
4. The pump is located under the tank on the right
side of machine. The pump delivers solution from
the tank to the scrub deck. Pull pump mounting
plate forward and down to expose pump.
5. Reverse steps to install.
4. PUMP MOUNTING PLATE
See graphic representation on previous page.
5. SOLENOID VALVE
The solenoid valve is mounted on the front of the scrub
deck, on left side.
The solenoid valve shuts off solution flow to scrub deck
whenever scrubbing stops. To repair or replace
solenoid valve, cut cable ties that secure it to deck.
86317500 CHARIOT SCRUBBER
Maintenance
43

Hide quick links: