CHECKING BATTERY SPECIFIC GRAVITY

Use a hydrometer to check the battery specific gravity.
CHECKING GRAVITY
a. Hydrometer Battery
b. Battery
NOTE: Do not take readings immediately after adding
distilled water, if the water and acid are not thoroughly
mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
°
°
@ 80
F (27
C)
1.265
1.225
1.190
1.155
1.120
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80°F (27°C),
the reading must be temperature corrected.
To find the corrected specific gravity reading when the
temperature of the battery electrolyte is other than 80°F
(27°C): Add (+) to the specific gravity reading 0.004 (4
points), for each 10°F (6°C) above 80° (27°C). Subtract
(-) from the specific reading 0.004 (4 points), for each
10°F (6°C) below 80°F (27°C).
BATTERY CONDITION
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
86317500 CHARIOT SCRUBBER

CHARGING BATTERIES

When servicing machine, avoid contact with
battery acid.
Batteries emit hydrogen gas. Explosion or fire can
result. Keep sparks and open flame away. Keep
covers open when charging.
Wear eye protection and protective clothing when
working with batteries.
Charge batteries in a well ventilated area.
Use a 36 volt, 20 amp maximum output DC charger
which will automatically shut off when the batteries are
fully charged.
1. Stop the machine in a clean, well ventilated area
next to the charger.
2. Turn "OFF" machine.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
3. Remove rear cover, unplug batteries from
machine, unlatch battery tray and pull out to
expose batteries.
Batteries emit hydrogen gas. Explosion or fire can
result. Keep sparks and open flame away. Keep
covers open when charging.
4. Check the electrolyte level in each battery cell.
Before charging, add just enough distilled water to
cover the plates. After charging is complete, add
just enough distilled water to bring up the level to
the indicator ring. If the water level is too high
before charging, normal expansion rate of the elec-
trolyte may cause an overflow resulting in a loss of
battery acid balance and damage the machine.