Kenmore 240-volt compact electric dryers Owner's Manual & Installation Instructions page 14

240-volt compact electric dryers
Hide thumbs Also See for 240-volt compact electric dryers:
Table of Contents

Advertisement

STEP 3. Attach a 3/4-inch, U.L.qisted,
strain relief to the hole below terminal
block opening, Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the power supply
cord through the strain relief.
STEP 4. Loosen or remove terminal block
screws. Connect the neutral wire (white
or center) of power supply cord under
the center screw of the terminal block.
STEP 5. Connect the other two wires
to outer terminal block screws. Tighten
all terminal block screws firmly.
External g round
connector
Neutral
grounding wire
(green/yellow)
Center s ilver-colored
terminalblockscrew
Neutral
wire
(white)
3 II
/4, U.L.-listed,
strainrelief
3-Wire Connection
with
Frame-Grounding
Conductor
STEP 6. Tighten the strain relief screws.
STEP 7. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
If local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire, see
the instructions on page 16.
Otherwise,
proceed with Knob
Installation.
See "INSTALL
KNOBS"
on page 20.
II. THREE-WIRE
ELECTRICAL
CONNECTION
(DIRECT WIRE)
Prepare cable as directed:
Electrical Shock Hazard
Turn power supply off before
connecting wires.
Use 10-gauge solid copper wire.
Electrically ground dryer.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
The dryer can be connected directly
to fused disconnect or circuit breaker
box with three-wire, flexible armored or
non-metallic
sheathed copper cable
(with grounding wire). All current-carrying
wires must be insulated.
A conduit connector must be installed at
junction box. Allow four feet of slack in the
line so dryer can be moved if servicing
is ever necessary.
GROUNDING INSTRUCTIONS
This appliance must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor
must be run with the circuit
conductors
and connected to the
equipment_grounding
terminal or
lead on the appliance.
STEP 1, Turn power supply off.
STEP la. Strip 3Vz inches of outer
covering from end of cable.
14