Scanning Variables - Cisco Aironet Wireless LAN Client Installation And Configuration Manual

Wireless lan client adapters, guide for ms-dos
Hide thumbs Also See for Cisco Aironet Wireless LAN Client:
Table of Contents

Advertisement

Driver Keywords and Settings
Table 3-7
Variable
LISTENDECAY
FASTLISTENDELAY

Scanning Variables

Additional system performance adjustments can be made with the following group of variables.
Table 3-8
Variable
SCANMODE
BEACONLISTENTO
PROBEENERGYTO
PROBERESPONSETO
Cisco Aironet Wireless LAN Client Adapters Installation and Configuration Guide for MS-DOS
3-12
Power Management Variables (continued)
Value
0–0xFFFF
0–0xFFFF
Scanning Variables
Value
ACTIVE,
PASSIVE,
ADVANCED
0–0xFFFF
0–0xFFFF
0–0xFFFF
Chapter 3
Description
(Optional)—Specifies the rate at which the
listen interval grows.
Default: 2
Used only in INFRASTRUCTURE mode
when POWERSAVE mode is PSP or
FASTPSP.
Listen interval begins at FASTLISTENTIME
and eventually decays to LISTENTIME.
(Optional)—Specifies the time to delay
immediately after a transmission before
beginning at FASTLISTENTIME.
Default: 200 Kusec (200ms)
Used only in INFRASTRUCTURE mode
when POWERSAVE mode is PSP or
FASTPSP.
Description
(Optional)—Determines the current scanning
mode used by the adapter.
Default: ACTIVE
(Optional)—Determines the amount of time
to listen for a beacon on each channel.
Default: 40 Kusec
Used only if SCANMODE = PASSIVE
(Optional)—Determines the amount of time
to listen for RF energy following a probe.
Default: 3 Kusec
Used only if SCANMODE = ACTIVE
(Optional)—Determines the amount of time
to wait for a probe response after energy is
detected on a channel.
Default: 20 Kusec
Used only if SCANMODE = ACTIVE
Installing the Software
OL-1744-02

Advertisement

Table of Contents
loading

Table of Contents