FUNCTION
Check Zones
Arm System
Quick Arm
(if programmed)
Bypass Zone(s)
Quick Bypass
(if programmed)
Silence Sounders
Burglary:
Fire or CO:
"Check":
Disarm System
Clear Alarm
Memory
Duress (if active
and connected to
Central Station)
Panic Alarms
(as programmed)
Chime Mode
Test Mode
Phone Access
if applicable
PROCEDURE
Press READY key.
Enter code. Press arming key desired:
(AWAY, STAY, NIGHT-STAY,
MAXIMUM, INSTANT)
Press #. Press arming key desired:
(AWAY, STAY, MAXIMUM, INSTANT)
Enter code. Press BYPASS [6] key.
Enter zone number(s) to be bypassed
(use 2-digit entries).
Enter code. Press BYPASS [6] key + [#].
Enter code. Press OFF [1] key.
Press OFF key.
Press any key.
Enter code. Press OFF [1] key. (OFF
need not be pressed if entry delay or an
alarm is active)
After disarming, enter code again.
Press OFF [1] key again.
Arm or disarm "normally", but
use your 4-digit Duress code to do so.
Press key [A], [B], or [C] for at least 2
seconds or press designated key pairs.
To turn ON or OFF: Enter code. Press
CHIME key.
To turn ON: Enter code. Press TEST key.
To turn OFF: Enter code. Press OFF key.
Consult Phone Access User's Guide that
accompanies the Phone Module.
COMMENTS
View faulted zones when system not
ready.
Arms system in mode selected.
Arms system in mode selected, quickly
and without use of a code.
Bypassed zones are unprotected and
will not cause an alarm if violated.
Bypasses all faulted zones
automatically.
Also disarms system. Memory of alarm
remains until cleared.
Memory of Alarm remains until cleared.
Determine cause.
Also silences sounders. Memory of
alarm remains until cleared.
Keypad beeps rapidly on entry if alarm
has occurred while absent. Alarm
display will remain upon disarming
until cleared.
Performs desired action and sends
silent alarm to Central Station.
See the Panic Keys section for
emergency functions programmed for
your system. Note: Keys "A", "B", and
"C" may have been programmed for
other functions.
The keypad will sound if doors or
windows are violated while system is
disarmed and chime mode is ON.
Tests alarm sounder and allows sensors
to be tested.
Permits system access remotely, via
Touch-tone phone.
– 45 –