TROUBLESHOOTING cont...
A hardware error was detected in in.xm.
• Restart the spa pack and start and stop all
pumps and blower.
• If error reappears, contact local dealer to
schedule a service call.
User tried to set input current rating lower
than the sum of current for all pumps.
• Increase in.xm current rating (and breaker) or
reduce pump size.
Input voltage is too low.
Either there is a problem with the terminal
connections or with the power line.
• Check input terminal connections to make
sure they are correctly wired and tightened.
• Have a certified electrician verify the quality of
the power line.
An in.xm fuse is blown.
Fan, blower, ozone, circulation pump,
fiber optic.
• Replace the blown fuse with an identically
rated replacement (SC-20, SC-25, etc.)
An in.xm fuse is blown.
Pump 2 and Pump 3, or a blower that is more
than 5 amps.
• Replace the blown fuse with an identically
rated replacement (SC-20, SC-25, etc.)
An in.xm fuse is blown.
Pump 2 and Pump 3, or a blower that is more
than 5 amps.
• Replace the blown fuse with an identically
rated replacement (SC-20, SC-25, etc.)