Minimum Installation - Kenmore 3405587 Owner's Manual And Installation Instructions

29-inch wide gas dryers
Table of Contents

Advertisement

RECESSED
AREA/CLOSET
INSTALLATION
INSTRUCTIONS
Check
governing
codes
and ordinances.
This dryer may be installed
in a recessed
area or closet.
The dryer
must not be installed
where
it
will be exposed
to water
and/or
weather.
* Proper
operation
of dryer cycles
requires
temperatures
above
45°F (at
lower temperatures,
the dryer
may not
shut off at the end of automatic
cycles
and drying
times will be extended).
* Use at least the minimum
installation
spacings
described
below.
This will
ensure
you have an adequate
clearance
for service
and proper
operation
including
flow of combustion
and ventilation
air,
and that you have a sufficient
distance
from combustible
construction.
* Be sure
your location
allows
for a
proper
exhaust
installation.
A gas dryer
must be exhausted
to the outdoors.
See pages
17-21 for complete
exhaust
requirements.
* Check
code
requirements.
Some
codes
limit or do not permit
installation
of clothes
dryers
in garages,
closets,
mobile
homes,
or sleeping
quarters.
Contact
your
local building
inspector.
NOTE:
No fuel-burning
appliances
may
be installed
in the same closet
as a dryer.
MINIMUM INSTALLATION
SPACING
minimum
ventilation
al'ea
**24 sq. in.
minimum
ventilation
81'ea
F-29"- 't F-*I" ÷11"1<- 28'/,0"
''
FrontView
Side View
(DoorNot Shown)
(DoorShown)
FrontView
(DoorWith Vent)
* Additional clearances forwall, doorand floor moldings maybe required.O"clearance
is acceptablebutnotrecommended.
** Openingisminimumfor closetdoor.Lonvered doorwith equivalent air
openings is acceptable.
*** Additional apaceis neededwhenexternal exhaustelbow isused. Canbe O"clearance
whenhouseexhausting islinedupdirectlywith dryerexhaust.
J:
3"
f
3"
T
• In the above
illustration,
the installation
spacing
is in inches and is the minimum
allowable.
• Additional
spacing
should
be considered
for ease
of installation
and servicing.
• If closet
door is installed,
the minimum
air openings
in top and bottom
are
required.
Louvered
doors
with equivalent
air openings
in top and bottom
are
acceptable.
* All installations
must be exhausted
outside.
Use at least the minimum
dimensions
indicated.
I1