  • Page 1 Website:http://www.sears.com ELECTRIC & GAS DRYER SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLES CORRECTLY BEFORE OFFERING SERVICE. MODEL : 796.8219# / 796.9219# 796.8102# / 796.9102#...
  • Page 2 OCT. 2009 PRINTED IN KOREA P/No.: MFL92119904...
  • Page 3: What To Do If You Smell Gas

    IMPORTANT SAFETY NOTICE The information in this service guide is intended for use by individuals possessing adequate backgrounds of electrical, electronic, and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
  • Page 4: Table Of Contents

    CONTENTS 1. SPECIFICATIONS ........................4 2. FEATURES AND BENEFITS ....................5 3. INSTALLATION INSTRUCTIONS .................... 6 4. COLUMBUS DRYER CYCLE PROCESS ..................9 5. COMPONENT TESTING INFORMATION ................10 6. MOTOR DIAGRAM AND SCHEMATIC..................13 7. CONTROL LAY - OUT ......................14 8. WIRING DIAGRAM ......................15 9.
  • Page 5: Specifications

    SPECIFICATIONS 796.8219#. 900 / 796.9219#. 900 REMARK ITEM 796.8102#. 900 / 796.9102#. 900 Color White / Ginger / Chili Pepper Material & Top Plate Spray Finish Door Trim Light Gray POWER SUPPLY 120V / 240V 60Hz (26A) AC 120V 250W (4.5A)
  • Page 6: Features And Benefits

    FEATURES AND BENEFITS Apply Model : 796.8219# / 796.9219#900 Apply Model : 796.8102# / 796.9102#900...
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS 3-1. POWER CORD 1) 4-wire connection IMPORTANT: A 4-wire connection is 3. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. required for mobile Tighten screw. homes and where local 4. Connect neutral wire (white or center wire) of codes do not permit the power supply cord to the center, silver colored use of 3 wire connections.
  • Page 8 2) 3-wire connection 3) Optional 3-wire connection Use where local codes permit connecting Use where local codes permit connecting cabinet-ground conductor to neutral wire. cabinet-ground conductor to neutral wire. 1. Remove center terminal block screw. 2. Remove appliance ground wire (green) from external ground connector screw.
  • Page 9: Connect Gas Supply Pipe (Gas Dryer Only)

    3-2. Connect Gas Supply Pipe (Gas Dryer ONLY) For further assistance, refer to section on Gas Requirements. 1. Make certain your dryer is equipped for use with the 3. Connect to gas supply pipe using a new flexible type of gas in your laundry room. Dryer is equipped stainless steel connector.
  • Page 10: Columbus Dryer Cycle Process

    DRYER CYCLE PROCESS Apply Model : 796.8219#. 900 / 796.9219#. 900 / .8102#. 900 / 796.9102#. 900 Steam Refresh Mid High Steam Sanitize Heavy duty Khaki / Jeans (796.8219#900, 796.9219#900 only) Workout wear Small Load Air Dry (796.8219#900, 796.9219#900 only) Rack Dry (796.8219#900, 796.9219#900 only)
  • Page 11: Component Testing Information

    COMPONENT TESTING INFORMATION When checking the Component, be sure to turn the power off, and do voltage discharge sufficiently. CAUTION Component Test Procedure Check result Remark 1. Thermal cut off Measure resistance of terminal If thermal fuse is open must •...
  • Page 12 Component Test Procedure Check result Remark 7. Heater Measure resistance of the · Electric type following terminal ®Á Terminal : 1 (COM) - 2 ®Á Resistance value : 10Ω ®Ë Terminal : 1 (COM) - 3 ¤Ł Resistance value : 10Ω ®Á...
  • Page 13 Component Test Procedure Check result Remark 13. Hi-limit Thermostat Measure resistance of terminal • Gas type (Auto reset) to terminal • Gas funnel- ① Resistance value ≒ ∞ ① Open at 203 ± 7°F (95 ± 5°C) Hi-limit ② Continuity < 1Ω ②...
  • Page 14: Motor Diagram And Schematic

    MOTOR DIAGRAM AND SCHEMATIC When checking Component, be sure to turn Power off, then do voltage discharge sufficiently. NOTE Contact On / Off by Centrifugal Switch STOP MODE RUN MODE (When Motor does not operate) (Motor operates) Centrifugal switch Centrifugal switch (Pull Drive forward)
  • Page 15: Control Lay - Out

    CONROL LAY - OUT PCB ASSEMBLY DISPLAY LAY-OUT PCB ASSEMBLY LAY-OUT...
  • Page 16: Wiring Diagram

    Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangrous operation. Verify proper operation after servicing. ELECTRIC DRYER WIRING DIAGRAM Apply Model : 796.8219#900 / 7096.8102#900 GAS DRYER WIRING DIAGRAM Apply Model : 796.9219#900 / 7096.9102#900...
  • Page 17: Steam Function

    STEAM FUNCTION 9-1. Steam Cycle Guide TEMP. MAXIMUM FABRIC FABRIC DEFAULT STEAM CONTROL AMOUNT LEVEL STATE TYPE TIME Comforter Single (1 each) Bedding 39 minutes STEAM Children’s SANITIZE 3 lbs. clothing Comforter Single (1 each) 20 minutes Shirts* 5 each STEAM REFRESH 10 minutes 8 lbs.
  • Page 18: Troubleshooting For Steam Dryer

    9-2. Troubleshooting for Steam Dryer PROBLEM SOLUTIONS POSSIBLE CAUSES This is steam condensation. Water drips from nozzle This is normal. The dripping water will stop after a short time. when Steam Cycle starts. The drum does not turn The drum is turned off and only tumbles This is normal.
  • Page 19: Diagnostic Test

    DIAGNOSTIC TEST 1. This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified. 2. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not activate it manually.
  • Page 20: Test 1 120Vac Electrical Supply

    Test 1 120V AC Electrical supply NOTE: To properly check power supply in case of floating neutral or high resistance connections, a load must be applied to the circuit. It is important that the power button be pressed while checking the voltages as described below. With the dryer plugged in, press the POWER button to turn on dryer.
  • Page 21: Power Connection

    When measuring power, be sure to wear insulated gloves, to and avoid an Caution electric shock. Trouble Symptom Check the Tab Relays Connection properly. Measurement Condition With Dryer Power On; Connector linked to Controller. 1.Power Connection < Table1 > : Connection of the Tab Relay with Heater (Elec) High Temperature Control below 68 ±...
  • Page 22 < Table 2 > : Connection of Tab Relay with PCB ASSEMBLY (Gas) Remark Color Harness Blue Wire Check the Matching color Between Harness wire and Tab Relay. Black Connector Housing (Black Housing – Black Tab Relay) Black Wire Connector Housing Tap relay 1 3.
  • Page 23: Test 2 Thermistor Test

    Test 2 Thermistor Test---Measure with Power Off Disconnect the NA6 connector from the main PCB. •Check all wiring Measure the resistance harness between the NA6-6 (GN) pin connections, and a chassis ground screw. wires and Is the resistance <1 Ω ? ground screws.
  • Page 24: Test 3 Motor Test

    Test 3 Motor test • Replace main In diagnostic test mode, press the START / PAUSE button. Is the voltage 120 VAC between WH1-1(WH) and BL3- 1 (BN)? With the connectors disconnected, • Recheck voltage at check the resistance between BL2-1 main PCB and (WH) and WH4-3 (BN).
  • Page 25: Test 4 Moisture Sensor

    Test 4 Moisture sensor NOTE: This test has two parts. The best test of the moisture sensing system is done in the diagnostic mode. This FUNCTIONAL TEST will test the sensor bars, wiring harness and PCB operation. If the results of this test are normal, the sensor system and PCB response are normal.
  • Page 26: Test 5 Door Switch Test

    Test 5 Door switch test NOTE: This test has two parts. The best test of the door switch system is done in the diagnostic mode. This FUNCTIONAL TEST will test the door switch, wiring harness and PCB operation. If the results of this test are normal, the door switch system and PCB response are normal.
  • Page 27: Test 6 Heater Switch Test - Electric Type

    Test 6 Heater switch test - Electric Type Enter diagnostic mode and • Check power supply. press the START/PAUSE button twice. Measure the voltage between YL3- 3 (WH) and the YL wire on the black tab relay. Is the voltage 240 VAC? Disconnect the YL3, black tab •...
  • Page 28: Test 7 Gas Valve Test - Gas Type

    Test 7 GAS Valve test - Gas Type FUNCTIONAL VALVE SYSTEM TEST 1. Verify gas supply is turned on and gas is present at the machine. 2. With the top plate removed, enter the diagnostic test mode and press the START/PAUSE button twice. Observe the area to the right of the drum at the front.
  • Page 29: Change Gas Setting (Natural Gas, Propane Gas)

    CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS) Warning After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas Orifice will result in fire. Conversion must be made by a qualified technician. Initially , Natural Gas mode is set. Propane Gas Orifice is on sale as a Service Part to authorized servicers only.
  • Page 30 GAS VALVE FLOW START KEY PUSH VALVE 1 ON (VALVE 2 OFF) IGNITER ON IGNITER TEMPERATURE ABOUT 2499°F(1343°C) FLAME DETECT OPEN IGNITER OFF 374°C(190°C) VALVE 2 ON GAS IGNITION FLAME DETECT CLOSE VALVE 2 OFF DRYING GAS IGNITION GAS VALVE STRUCTURE START VALVE 1 IGNITER...
  • Page 31: Disassembly Instructions

    DISASSEMBLY INSTRUCTION Disassemble and repair the unit only after pulling out power plug from the outlet. TOP PLATE WARNING ! When you disassemble the top plate, be sure to take gloves and careful plate s edge. Failure to do so can cause serious injury.
  • Page 32 Pull out the drawer a⁄–aa Lift out the water tank. Remove 2 screws on the control panel.
  • Page 33 W ARNING ! When you disassemble the control panel, be sure to take gloves and careful panel frame s edge. Failure to do so can cause serious injury. Remove 1 screw on the control panel frame. Disconnect the connectors. Pull the control panel assembly upward and then forward.
  • Page 34 COVER CABINET 1. Disassemble the top plate. 2. Disassemble the control panel assembly. 3. Disassemble the door assembly. 4. Remove 2 screws. 5. Remove 4 screws from the top of cabinet cover. 6. Disconnect the harness of door switch.
  • Page 35 Remove 2 screws on the frame body. Push the Guide ASM to the back side and then lift it. Separate hoses from the pump and generator. Lift a pump and a generator up.
  • Page 36 Remove 4 screws on the frame body and then disassemble the frame body. Remove 4 screws on the panel frame and then disassemble the panel frame.
  • Page 37: Drum Assembly

    TUB DRUM [FRONT] WARNING ! When you disassemble the lamp connector, be sure to take gloves and careful cabinet edge. Failure to do so can cause serious injury. Open the top plate. Remove Cover Cabinet. Disconnect the door lamp and electro sensor connector.
  • Page 38: Dryer Exhaust Change

    DRYER EXHAUST CHANGE WARNING ! When you disassemble and install ventilation, be sure to take gloves and careful exhaust edge. Failure to do so can cause serious injury. Remove screw & exhaust duct. PORTION “A” Detach and remove the bottom, left or right side knockout as desired.
  • Page 39: Filter Assembly

    FILTER ASSEMBLY Remove the filter. Remove 3 screws. Pull the grill. Disconnect electro sensor. BLOWER HOUSING Open the top plate. Remove the Cover Cabinet and Tub Drum [Front]. Remove the Drum assembly. Remove 2 screws and cover(Air guide). Remove the bolt and washer. Pull the fan.
  • Page 40: Air Duct

    AIR DUCT Open the top plate. Remove the Cover Cabinet. Remove filter and 2 screws. Pull the air duct towards the front. ROLLERS Open the top plate. Remove the Cover Cabinet and Tub Drum [Front]. Remove the Drum assembly and Tub Drum [Rear]. Disconnect Air duct from the Tub Drum [Front].
  • Page 41: Exploded View

    EXPLODED VIEW 13-1. Control Panel & Plate Assembly A211 A210 A130 A120 A140 A110...
  • Page 42: Panel Drawer Assembly & Guide Assembly

    13-2. Panel Drawer Assembly & Guide Assembly K503 K508 K502 K506 K501 K505 K504 K507 A090 A172 A161 A160 A171 A170 A350...
  • Page 43: Cabinet & Door Assembly

    13-3-2. Cabinet & Door Assembly: Gas type A590 A700 A800 A390 A131 A600 A300 A330 A550 A500 A320 A530 A510 A310 A430 A520 A525 A410 A540 A400 A420 A460 A450...
  • Page 44: Drum & Motor Assembly : Electric Type

    13-4-2. Drum & Motor Assembly: Gas type F200 K400 K420 K410 K120 K140 K100 K130 K250 K251 K310 K320 K330 K222 K340 K221 K620 K224 K230 K210 K250 K360 K350 K610 K560 K550 K251 K240 K530 K640 K651 K515 K655 K510 K520 K540 M141...