Diagnostics - Parking Lights Flash Rate - Autostart AS-6320 FM Installation Manual

Automatic transmission remote starter and full alarm system
Hide thumbs Also See for AS-6320 FM:
Table of Contents

Advertisement

Diagnostics - Parking Lights Flash Rate

Flashes
Doors locked, Starter Kill armed.
End of Run Time.
TRUNK
1
signal received by the Module.
START
Cold Weather Mode cancelled.
Cannot start after maximum number of attempts is reached.
Run Time cancelled.
Exiting remote valet mode
2
Remote start attempt cancelled by remote.
Exiting ignition valet mode
Doors unlocked, Starter Kill disarmed.
Entering Cold Weather Mode
3
Entering remote valet
Entering ignition valet
+12 volts detected on the Brake line; cranking cancelled
4
Entering Tach Learning
New Transmitter learnt
5
Tach learnt
Remote start attempt was made with a Tach or a vacuum signal detected before
6
cranking
8
Unit reset: occurs when the unit is reset to factory defaults
10
The Hood Switch line went to ground during cranking or run time
1 – pause – 2
There was an attempt to start the vehicle while the Module was in Valet Mode.
There was an attempt to start the vehicle while the Module was in Home Valet
2 – pause – 2
Mode.
ON solid
Cold Weather Mode: the Brake Pedal is being held down
The Hood is up and the Hood Switch line went to ground. This is step one of the
ON 2 sec.
Programming Mode
First press of the
ON 3 sec.
Entering Home Valet Mode
ON 4 sec.
or
LOCK
If the Hood Pin-switch has been pressed twice: the Unit went into step 1 of the
Programming cycle and no Transmitter activity was detected for 20 seconds
ON 25 sec.
Or the Unit went into step 1 of the Transmitter Code Learning procedure and no
activity was detected for a few seconds. The Unit has exited the Transmitter Code
Learning procedure.
If the Module gives irregular flashes (1 to 10 flashes followed by a pause, followed
Irregular
by more flashes), it is in Playback Mode. This occurs when the Hood-switch line is
flashed 3 times.
Constant flashes
Panic Mode set off.
up to 30 sec.
P.18
Description
button pressed
button under Safe Start.
START
pulse (if door pulse is configured to 4 sec.)
UNLOCK
Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-6320