Diagnostics – Parking Light Flash Table
Flashes
1
2
3
3 slow flashes...
4
5 Slow
5 Fast
6
8
10
1 – pause – 2
2 – pause – 2
ON SOLID for 3
seconds....
ON continuously
ON continuously
ON 2 seconds
ON 4 seconds
ON 20 seconds
ON 25 SEC.
CONSTANT FLASHES
UP TO 60 SEC.
User Guide
• Doors locked, Alarm and starter kill armed.
• Run time has expired.
button pressed.
TRUNK
• Remote start attempt cancelled by remote.
• Doors unlocked, starter kill disarmed.
• Exiting ignition valet
• Entering cold weather mode
• Entering ignition valet
• Entering or exiting Ready Mode
...after a failed start attempt
• +12 V detected on the brake input wire either while cranking or during run time.
• Entering multi-speed tach programming.
• Start attempt failed because no tach signal has been programmed.
• Tach signal programmed.
• New transmitter programmed.
• A remote start was attempted while a tach-before-crank signal was detected before cranking.
• Unit reset
• A ground (-) signal was detected on the hood pin input wire.
• There was a remote start attempt while the vehicle was in valet mode.
• Failed start: vehicle's low battery voltage.
• There was an attempt to start the vehicle while the module was in valet mode.
...followed by 1 flash
...followed by 3 flashes
• Idle mode: Idle mode is engaged
• Run time: The vehicle has been remote started and is in run time.
While the brake pedal is pressed.
• The hood has been opened and a ground (-) signal has been detected on the hood pin input
wire.
• Locking or unlocking a door (with Door pulses configured to 4 sec.)
• The hood pin has been flashed and you now have access to the programming options.
• The Hood Pin-switch has been pressed twice: the Unit went into step 1 of the Programming
Centre procedure, and no Transmitter activity was detected for 20 seconds.
• Or the Unit went into step 1 of the Transmitter Programming procedure and no activity was
detected for a few seconds. The Unit has exited the Transmitter Programming procedure.
• Panic Mode is activated.
• In Siren or Horn Mode: Alarm condition generated by an intrusion, or when the System is
powered up.
Description
• Start signal received by the module.
• Cold weather mode cancelled.
• Exiting remote valet
• Power-up reset.
• Entering remote valet.
• Entering extended run time.
The module did not detect a tach signal.
Exiting cold weather mode
Entering cold weather mode
Confirms that cold weather mode is engaged