Download Print this page

Diagnostics - Parking Lights Flash Rate - Autostart AS-6105 SH/SR Quick Manual

Hide thumbs Also See for AS-6105 SH/SR:

Advertisement

VIII. Chirps
Chirps
1
2
3
4
5
Siren or Horn Chirp Timing adjustment.
In Horn Mode: alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up. The Horn will sound for
Constant up to 30 seconds
In Siren Mode: alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up. The Siren will sound for
Constant up to 60 seconds
IX. Diagnostics - Parking Lights Flash Rate
Flashes
1
2
3
4
5
6
8
10
1 – pause – 2
There was an attempt to start the vehicle while the Module was in Valet Mode.
2 – pause – 2
There was an attempt to start the vehicle while the Module was in Home Valet Mode.
ON solid
Cold Weather Mode: the Brake Pedal is being held down.
The Hood is up and the Hood Switch line went to ground. This is step one of the Programming
ON 2 sec.
ON 3 sec.
First press of the START button under Safe Start.
ON 4 sec.
ON 25 sec.
Irregular
Constant flashes
In Horn Mode: Alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up.
up to 30 sec.
Constant flashes
In Siren Mode: Alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up.
up to 60 sec.
AS-6105 SH/SR Quick Programming Guide
LOCK and ARM the system.
LOCK confirmation.
Entering Mode 1 in Programming Options.
Start attempt when the Engine is already running under remote control.
Disarmed Notification
UNLOCK and disarm.
Transmitter learnt.
Entering Electronic Valet.
Entering Mode 2 in Programming Options.
LOCK and arm while a zone is left unprotected.
Entering Mode 3 in Programming Options.
Door zone left unprotected.
UNLOCK and disarm: an intrusion was detected.
Entering the Tach Learning procedure.
30 sec. (honk – pause – horn – pause ...)
60 sec.
Doors locked, Alarm and Starter Kill armed.
End of Run Time.
Run Time cancelled.
TRUNK button pressed
START signal received by the Module.
Cold Weather Mode cancelled.
Cannot start after maximum number of attempts is reached.
Doors unlocked, Alarm and Starter Kill disarmed.
Entering Cold Weather Mode.
Remote start attempt cancelled by remote.
+12 V where detected on the brake line and cranking was cancelled.
Entering the Tach Learning procedure.
New Transmitter learnt.
Tach learnt.
A remote start was attempted while a Tach or a vacuum signal was detected before cranking.
Unit reset: occurs when the Unit is reset to the factory defaults.
The Hood Switch line went to ground during cranking or Run Time.
Modes.
The hood was opened and the hood switch line went to ground. This is step one of the programming centre.
Lock or Unlock pulse (if door pulse is configured to 4 sec.)
If the Hood Pin-switch has been pressed twice (down-up / down, up): the Unit went into step 1 of the Programming cycle and no
Transmitter activity was detected for 20 seconds
Or the Unit went into step 1 of the Transmitter Code Learning procedure and no activity was detected for a few seconds. The Unit
has exited the Transmitter Code Learning procedure.
If the unit gives irregular signals (1 to 10 flashes followed by a pause, followed by further flashes), the system is playing back Start
Failure Codes. This occurs when the Hood Pin-switch is pressed three times (down, up / down, up / down, up)
Description
Description
P. 5

Advertisement

loading

This manual is also suitable for:

As-6105 shAs-6105 sr