Removing And Replacing A Fru; Adding A Fru Into A Domain - Fujitsu SPARC ENTERPRISE M4000 Service Manual

Fujitsu computer hardware user manual
Hide thumbs Also See for SPARC ENTERPRISE M4000:
Table of Contents

Advertisement

Note – For a PCI cassette, type the cfgadm -c disconnect command to
disconnect the component from the domain.
The Ap_Id is shown in the output of cfgadm.
3. Type the cfgadm command to confirm the component is now disconnected.
# cfgadm -a
Ap_Id
Condition
iou#0-pci#0
unknown
iou#0-pci#1
iou#0-pci#2
4.2.2

Removing and Replacing a FRU

Once the FRU has been removed from the domain, see
FRU" on page 4-7
4.2.3

Adding a FRU Into a Domain

1. From the Solaris prompt, type the cfgadm command to connect the component
to the domain.
# cfgadm -c configure Ap_Id
The Ap_Id is shown in the output of cfgadm.
2. Type the cfgadm command to confirm the component is now connected.
# cfgadm -a
Ap_Id
Condition
iou#0-pci#0
iou#0-pci#1
iou#0-pci#2
iou#0-pci#0
Type
Receptacle
etherne/hp
disconnected unconfigured
fibre/hp
connected
pci-pci/hp
connected
"Removing and Replacing a
iou#0-pci#0
Type
Receptacle
etherne/hp
connected
fibre/hp
connected
pci-pci/hp
connected
Chapter 4
FRU Replacement Preparation
for example.
Occupant
configured
ok
configured
ok
for example.
Occupant
configured
ok
configured
ok
configured
ok
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents