Fujitsu SPARC ENTERPRISE M4000 Service Manual page 223

Fujitsu computer hardware user manual
Hide thumbs Also See for SPARC ENTERPRISE M4000:
Table of Contents

Advertisement

13. Continue with the appropriate installation procedure:
If you are adding a new SPARC64 VII–equipped CPU module to a domain
configured with SPARC64 VI processors, continue with
CPU Module to a Domain Configured With SPARC64 VI" on page
If you are upgrading an existing SPARC64 VI CPU module in an existing domain
to SPARC64 VII processors, continue with
Module to SPARC64 VII on an Existing Domain" on page
▼ Adding a SPARC64 VII CPU Module to a
Domain Configured With SPARC64 VI
This procedure must be preceded by
an Existing Domain" on page
before continuing.
1. Install the CPUM in the server.
For instructions, refer to the "CPU Module Replacement," chapter in the Sun
SPARC Enterprise M4000/M5000 Servers Service Manual. Note that this procedure
involves powering down the entire server.
Caution – After installing the CPU module, you must reconnect the power cable to
the power supply.
2. Log in to the XSCF again, using an account with platadm or fieldeng
privileges.
Perform an initial diagnosis of the newly installed CPU module.
XSCF> testsb 01
The following example shows a test after adding PSB#01:
XSCF> testsb 01
Initial diagnosis is about to start. Continue? [y|n] : y
Initial diagnosis is executing.
Initial diagnosis has completed.
XSB Test Fault
---- ------- --------
01 Passed Normal
"Upgrading a SPARC64 VI CPU
"Preparing to Add SPARC64 VII Processors to
11. If you have not completed that procedure, do so
Chapter 12
"Adding a SPARC64 VII
13.
15.
CPU Module Replacement 12-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents