Confirmation Of Dimm Information - Fujitsu SPARC ENTERPRISE M4000 Service Manual

Fujitsu computer hardware user manual
Hide thumbs Also See for SPARC ENTERPRISE M4000:
Table of Contents

Advertisement

Location Number
6
7
8
Caution – To replace or install a DIMM, do not fail to confirm the DIMM
information and comply with the conditions to mount the memory.
11.2.1

Confirmation of DIMM Information

Confirm the DIMM information (size/rank) in the following way.
Execute the showhardconf(8) command on XSCFU.
The Type field shows the DIMM size and the DIMM rank.
showhardconf
CODE EXAMPLE 11-1
XSCF> showhardconf
...
MBU_B Status:Normal; Ver:0101h; Serial:78670002978: ;
+ FRU-Part-Number:CF00541-0478 01 /541-0478-01 ;
+ Memory_Size:64 GB;
...
MEM#0A Status:Normal;
+ Code:c1000000000000004572T128000HR3.7A 252b-04123520;
+ Type:1B; Size:1 GB;
MEM#0B Status:Normal;
+ Code:c1000000000000004572T128000HR3.7A 252b-04123e25;
+ Type:1B; Size:1 GB;
MEM#1A Status:Normal;
+ Code:c1000000000000004572T128000HR3.7A 252b-04123722;
+ Type:1B; Size:1 GB;
MEM#1B Status:Normal;
+ Code:c1000000000000004572T128000HR3.7A 252b-04123b25;
+ Type:1B; Size:1 GB;
...
Component
MEM#1A, Memory Slot (Group A)
MEM#0B, Memory Slot (Group B)
MEM#0A, Memory Slot (Group A)
Chapter 11
Memory Board Replacement
11-9