Accessing The Tape Drive Backplane Of The Sparc Enterprise M4000 Server - Fujitsu SPARC ENTERPRISE M4000 Service Manual

Fujitsu computer hardware user manual
Hide thumbs Also See for SPARC ENTERPRISE M4000:
Table of Contents

Advertisement

6.3.5
Accessing the Tape Drive Backplane of the SPARC
Enterprise M4000 Server
Caution – There is an electrical hazard if the power cords are not disconnected. All
power cords must be disconnected to completely remove power from the server.
Caution – Use proper ESD grounding techniques when handling components. See
"Safety Precautions" on page
1. Power off the server.
This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See
Server Off Using Software" on page
Caution – To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Note – When drawing out the SPARC Enterprise M4000/M5000 Server to the front,
release the cable tie holding the PCI cables on the rear of the server.
2. Remove the fan cover.
This step includes deploying the rack's antitilt features (if applicable), sliding the
server out of the equipment rack, removing the 60-mm fan units and removing
the fan cover. See
3. Remove the 60-mm fan backplane.
This step includes removing the cable connectors, loosening the captive screws
and removing the 60-mm fan backplane. See
Backplane" on page
1-1.
4-12.
"Removing the Fan Cover" on page
10-11.
Chapter 6
"Powering the
5-8.
"Removing the 60-mm Fan
Storage Devices Replacement