Caution – After installing the CPU module, you must reconnect the power cable to
the power supply.
9. Log in to the XSCF again, using an account with platadm or fieldeng
privileges.
10. Perform an initial diagnosis of the newly installed CPU module.
XSCF> testsb 01
The following example shows a test after adding PSB#01 to a SPARC Enterprise
M5000 server:
XSCF> testsb 01
Initial diagnosis is about to start. Continue? [y|n] : y
Initial diagnosis is executing.
Initial diagnosis has completed.
XSB Test Fault
---- ------- --------
01 Passed Normal
11. Confirm that the installed CPU module is recognized by the server and that the
error indicator asterisk (*) is not displayed.
XSCF> showhardconf -M
12. Confirm that no error has occurred.
XSCF> showlogs error -v
XSCF> showstatus
13. Change the key position on the operator panel from Service to Locked.
14. Power on the existing domains.
XSCF> poweron -a
15. Set the following for the added CPU module:
Set up XSB for the added CPU module.
Set up the domain.
Chapter 12
CPU Module Replacement
12-9