Updates Of The Sparc Enterprise M3000 Server Site Planning Guide; Electrical Specifications - Fujitsu SPARC Enterprise M3000 Product Notes

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

Updates of the SPARC Enterprise M3000 Server
Site Planning Guide
The following information supersedes the information in the SPARC Enterprise
M3000 Server Site Planning Guide.

Electrical Specifications

This section explains the electrical specifications of the M3000 server.
Note – The electrical power values in
the fully configured server. The actual values may differ from these values,
depending on the server configuration.
Electrical Specifications
TABLE 3-3
Item
Input voltage
Number of power cords
Power cord length
Redundancy
*
Rated current
Frequency
Maximum power
consumption
Apparent power
Heat dissipation
Power factor
Rush current
Leakage current
*. In a redundant configuration, the rated current per cord is half the value shown in
†. This value represents the current for each power cord.
Specification
CPU: 2.52 GHz
100 to 120 VAC
200 to 240 VAC
2 (1 cord for each power supply unit)
3 m/9.84 ft
1 + 1 redundant configuration
4.80 A
2.59 A
50/60 Hz
470 W
460 W
480 VA
517 VA
1,603.7 BTU/hr
1,569.6 BTU/hr
(1,692 kJ/hr)
(1,656 kJ/hr)
0.98
0.89
25 A or less
25 A or less
1.75 mA or less
1.75 mA or less
are the maximum values based on
TABLE 3-3
CPU: 2.75 GHz
100 to 120 VAC
2 (1 cord for each power supply unit)
3 m/9.84 ft
1 + 1 redundant configuration
5.15 A
50/60 Hz
505 W
515 VA
1,723.1 BTU/hr
(1,818 kJ/hr)
0.98
25 A or less
1.75 mA or less
TABLE 3-3
.
Information About Hardware
200 to 240 VAC
2.81 A
500 W
562 VA
1,707.9 BTU/hr
(1,802 kJ/hr)
0.89
25 A or less
1.75 mA or less
13

Advertisement

Table of Contents
loading

Table of Contents