Fujitsu M304X Series Oem Manual page 95

Fujitsu line printer oem manual
Hide thumbs Also See for M304X Series:
Table of Contents

Advertisement

6.4.3
DTR
line
The DTR line protocol is the same as the Reverse Channel line protocol.
This signal is turned from off (1) to on (0) under the following conditions:
. Printer is in the start state and,
. The interface buffer is empty or almost empty.
This signal is turned from on to off under one of the following conditions:
. Printer is in the stop state (error occured,
operator pressed the START/STOP switch) or,
. The interface buffer is almost full.
If this line protocol is enabled, the printer received data via the RD
Note:
line whether the DTR signal is on or off.
For timing details, see Figure 6.7.
6.4.4
RTS
line
The RTS line protocol is the same as the Reverse Channel line protocol.
is
signal
. Printer is in the start state and,
. The interface buffer is empty or almost empty.
This signal is turned from on to off under one of the following conditions:
. Printer is in the stop state or,
. The interface buffer is almost full.
Note:
This protocol enables the connection of a printer operating as data
terminal equipment (DTE) to a host operating as DTE.
protocol is not used to connect this printer to a host operating as data
circuit
a Status Request command when this protocol is enabled.
For timing details, see Figure 6.8.
6 - 20
protocol
protocol
turned from off (1) to on (0)
terminating
equipment
cover open, end of forms, or
under the following conditions:
However,
addition, th:is
In
this
printer ignores

Advertisement