Procedure
8-2
• Cleaning sheet
• Q-Tips
NOTICE: Cleaner F2 should be used for steel rollers.
This section provides instructions on how to clean each section of
the scanner.
WARNING
Wait at least 3 minutes after turning off the power before cleaning.
Cleaning the front-side lamp
Upper transport unit
Lever
Power switch
Lamp socket covers
1 Turn off the power switch.
Operator
2 Open the upper transport
panel
unit. (See page 4-2)
3 Remove the two lamp
socket covers (U-shaped
spring clips) by pulling
them out of their positions.
M3099EX/EH OEM Manual