Fujitsu M3099EX/EH Oem Manual page 63

Image scanner
Table of Contents

Advertisement

A #19
B #19
M3099EX/EH OEM Manual
Control register A#18
Control register B#18
X"00" is set when the power is turned on or when a CLEAR
command is issued for initialization.
• This register reserved for future.
b7
A #18
0
0
0
0
B #18
Control register A#19
Control register B#19
X'00' is set when the power is turned on or when a CLEAR
command is issued for initialization.
b7
0
*1: If the built-in patterns are valid, 0 to 2 ('000' to '010') can be
selected.
b0
0
0
0
0
b0
0
Read density specification
0: 8 steps (Control register #1 is valid.)
1: 256 steps (Control register #20 is valid.)
Halftone processing method specification
0: Dithering
1: Error diffusion
pattern number specification (*1)
0 0 0 : Normal
0 0 1 : Soft
0 1 0 : Sharp
0 1 1
1 0 0 : Three types (0 to 2) if the built-in
1 0 1 patterns are valid.
1 1 0 : Eight types (0 to 7) if the downloading
1 1 1 is enabled.
Download/built-in
patterns
0: The patterns built into the device are valid.
1: The download patterns are valid.
INTERFACE
SPECIFICATIONS
3-35