Fujitsu M3099EX/EH Oem Manual page 61

Image scanner
Table of Contents

Advertisement

M3099EX/EH OEM Manual
Control register A#10 to #17
Control register B#10 to #17
Picking area (main window) setting register
#10
#11
#12
b7
b0
b7
b0
b7
b0
MSB
LSB
MSB
Picking in main scanning
X1
Y1
*1
Y2
Operation error occurs when the values of X1 + X2 [(#10, #11) +
(#12, #13)] and Y1 + Y2 [(#14, #15) + (#16, #17)] area more than
the values shown below.
Scanner
X1 + X2
M3099EX
4864
M3099EH
3456
#13
#14
#15
b0
b7
b0
b7
b0
b7
LSB MSB
LSB MSB
Picking in subscanning
X2
Y1
X1
X2
Picking
area
Document surface
Left edge of document
Y1 + Y2
6912
6912
#16
#17
INTERFACE
b7
b0
b7
b0
SPECIFICATIONS
LSB
Y2
Upper edge
of document
3-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

M3099exM3099eh

Table of Contents