1/16 - 1/8 - 1/4 din limit controllers
Hide thumbs Also See for P8700 - Core 2 Duo Processor:

Advertisement

Quick Links

1
1
1
/
-
/
-
/
DIN LIMIT CONTROLLERS
16
8
4
CONCISE PRODUCT MANUAL (59333-2)
CAUTION:
Installation should be only performed by
technically competent personnel. Local Regulations
regarding electrical installation & safety must be observed.
1. INSTALLATION
The models covered by this manual have three different DIN case sizes (refer to
section 9). Some installation details vary between models. These differences have
been clearly shown.
Note: The functions described in sections 2 thru 8 are common to all models.
Installing Option Modules
1
/
Din Size Instruments
16
CPU PCB
Mounting Struts
Option Module A
Option Module 1
(Fixed Limit Relay)
Option Module 3
Option Module 2
PSU PCB
1
1
/
&
/
Din Size Instruments
8
4
CPU PCB
Mounting Struts
Option Module B
( not used on Limit
Option Module A
Controllers)
Option Module 2
Option Module 3
Option Module 1
PSU PCB
(Fixed Limit Relay)
To access module A, first detach the PSU and CPU boards from the front by lifting
first the upper, and then lower mounting struts. Gently separate the boards.
a.
Plug the required option modules into the correct connectors, as shown below.
b.
Locate the module tongues in the corresponding slot on the opposite board.
c.
Hold the main boards together while relocating back on the mounting struts.
d.
Replace the instrument by aligning the CPU and PSU boards with their guides
in the housing, then slowly push the instrument back into position.
Note: Option modules are automatically detected at power up.
Option Module Connectors
1
/
Din Size Instruments
16
Option Slot 1
Option Slot A
(Fixed Limit
Connectors
Relay)
PL5 & PL6
Option Slot 2
Option Slot 3
Connector
Connector
PL4A
PL4B
1
1
/
&
/
Din Size Instruments
8
4
Option Slot B
(not used on
Limit Cont rollers)
Option Slot 2
Connector
PL4A
Option Slot 1
(Fixed Limit
Relay)
Option Slot A
Connectors
PL5 & PL6
Option Slot 3
Connector
PL4B
Panel-Mounting
The mounting panel must be rigid, and may be up to
6.0mm (0.25inch) thick. Cut-out sizes are:
Cut-Out Dim A
Cut-Out Dim B
1
1
1
/
&
/
Din = 45mm
/
Din = 45mm
16
8
16
1
1
1
/
Din = 92mm
/
&
/
Din = 92mm
4
8
4
A
For n multiple instruments mounted side-by-side, cut-out
1
1
1
A is 48n-4mm (
/
&
/
Din) or 96n-4mm (
/
Din)
Tolerance +0.5, -0.0mm
16
8
4
Slide mounting clamp
over the instrument
Mounting Panel
housing towards rear face
of mounting panel until
Instrument
the tongues engage in
Housing
ratchets and instrument is
clamped in position.
Ratchets
Gasket
Hold instrument firmly in
position (apply pressure
to bezel only)
CAUTION:
Do not remove the panel gasket; it is a seal against dust and
moisture.
Rear Terminal Wiring
USE COPPER CONDUCTORS (EXCEPT FOR T/C INPUT)
Single Strand wire gauge: Max 1.2mm (18SWG)
1
/
Din Size Instruments
16
1
1
/
&
/
Din Size Instruments
8
4
These diagrams show all possible option combinations. The actual
connections required depends on the exact model and options fitted.
CAUTION:
Check information label on housing for correct operating
voltage before connecting supply to Power Input
Fuse: 100 – 240V ac – 1amp anti-surge
24/48V ac/dc – 315mA anti-surge
Note: At first power-up the message
is displayed, as described in
section 6 of this manual. Access to other menus is denied until configuration
mode is completed
2. SELECT MODE
Select mode is used to access the configuration and operation menu functions.
B
It can be accessed at any time by holding down
and pressing
In select mode, press
or
to choose the required mode, press
An unlock code is required to prevent unauthorised entry to Configuration, & Setup
modes. Press
or
to enter the unlock code, then press
Mode
Upper
Lower
Description
Display
Display
Operator
Normal operation
Set Up
Tailor settings to the application
Configuration
Configure the instrument for use
Product Info
Check manufacturing information
Note: The instrument will always return automatically to Operator mode if
there is no key activity for 2 minutes.
3. CONFIGURATION MODE
First select Configuration mode from Select mode (refer to section 2).
Press
to scroll through the parameters, then press
value. Press
to accept the change, otherwise parameter will revert to previous
value. To exit from Configuration mode, hold down
and press
Select mode.
Note: Parameters displayed depends on how instrument has been configured.
Refer to user guide (available from your supplier) for further details.
Parameters marked * are repeated in Setup Mode.
Parameter
Lower
Upper
Adjustment range & Description
Display
Display
Input
See following table for possible codes
Range/Type
Code Input Type &
Code
Input Type &
Code Input Type &
Range
Range
L L L L
C C C C
bC
bC
bC
bC
B: 100 - 1824 ºC
.
L: 0.0 - 537.7 ºC
P24F
P24F
P24F
P24F
L L L L
F F F F
bF
bF
bF
bF
B: 211 - 3315 ºF
L: 32.0 - 999.9 ºF
.
CC
CC
CC
CC
C: 0 - 2320 ºC
NC
NC
NC
NC
N: 0 - 1399 ºC
PTC
PTC
PTC
PTC
CF
CF
CF
CF
C: 32 - 4208 ºF
NF
NF
NF
NF
N: 32 - 2551 ºF
PtF
PtF
PtF
PtF
JC
JC
rC
rC
P P P P t t t t
JC
JC
J: –200 - 1200 ºC
rC
rC
R: 0 - 1759 ºC
Pt
Pt
Pt
Pt
JF
JF
JF
JF
J: –328 - 2192 ºF
rF
rF
rF
rF
R: 32 - 3198 ºF
j j j j
C C C C
J: –128.8 - 537.7 ºC
SC
SC
SC
SC
S: 0 - 1762 ºC
.
j j j j
F F F F
J: –199.9 - 999.9 ºF
SF
SF
SF
SF
S: 32 - 3204 ºF
.
KC
KC
KC
KC
tC
tC
tC
tC
K: –240 - 1373 ºC
T: –240 - 400 ºC
KF
KF
KF
KF
K: –400 - 2503 ºF
tF
tF
tF
tF
T: –400 - 752 ºF
k k k k
C C C C
t t t t
C C C C
K: –128.8 - 537.7 ºC
T: –128.8 - 400.0 ºC
.
.
K K K K
F F F F
t t t t
F F F F
K: –199.9 - 999.9 ºF
T: –199.9 - 752.0 ºF
.
.
LC
LC
LC
LC
L: 0 - 762 ºC
PtRh20% vs. 40%:
P24C
P24C
P24C
P24C
0 - 1850 ºC
LF
LF
LF
LF
L: 32 - 1403 ºF
Note: Decimal point shown in table indicates temperature resolution of 0.1°
Parameter
Lower
Upper
Adjustment range & Description
Display
Display
Scale Range
Scale Range Lower Limit +100
Upper Limit
to Range Maximum
Scale Range
Range Minimum to
Scale Range Upper Limit -100
Lower Limit
Decimal point
=XXXX, =XXX.X, =XX.XX, =X.XXX
position
(non-temperature ranges only)
±Span of controller
Process Variable
Offset
(see
CAUTION
note at end of section)
High Limit.
Limit relay is energised when
Limit Action
process "safe" (PV < Limit Setpoint)
Low Limit.
Limit relay is energised when
process "safe" (PV > Limit Setpoint)
Setpoint Upper
Current Setpoint to Scale Range maximum
Limit
Setpoint Lower
Scale Range minimum to Current Setpoint
Limit
Process High Alarm
Process Low Alarm
Alarm 1Type
Deviation Alarm
Band Alarm
No alarm
High Alarm 1
value*
Scaled Range Minimum to
Low Alarm 1
scaled Range Maximum in display units
value*
Band Alarm 1
1 LSD to span from setpoint in display units
value*
Dev. Alarm 1
+/- Span from setpoint in display units
value*
Alarm 1
! ! ! !
1 LSD to full span in display units
Hysteresis*
Parameter
Lower
Upper
Display
Display
Alarm 2 Type*
.
High Alarm 2
to enter.
value*
Low Alarm 2
to proceed.
value*
Default
Band Alarm 2
value*
Unlock
Dev. Alarm 2
Codes
Value*
None
Alarm 2
! ! ! !
Hysteresis*
Mm
Mm
Mm
Mm
None
" " " "
# # # #
Output 2 Usage
or
to set the required
, to return to
Default
Value
Linear Output 2
! ! ! !
Range
Range
Retransmit
PtRh20% vs 40%:
Output 2 Scale
(display value at which output
32 - 3362 ºF
maximum
Retransmit
Pt100: –199 - 800 ºC
Output 3 Scale
(display value at which output
Pt100: –328 - 1472 ºF
minimum
C C C C
Pt100: –128.8 - 537.7 ºC
# # # #
.
Output 3 Usage
F F F F
Linear Output 3
Pt100: –199.9 - 999.9 ºF
.
! ! ! !
Range
0 - 20 mA DC
Retransmit
4 - 20 mA DC
Output 3 Scale
(display value at which output
maximum
0 - 50 mV DC
Retransmit
.
10 - 50 mV DC
Output 3 Scale
(display value at which output
0 - 5 V DC
minimum
1 - 5 V DC
0 - 10 V DC
Display Strategy
$ $ $ $
2 - 10 V DC
% % % %
Default
Serial
Mm
Mm
Mm
Mm
Value
Communications
Mm
Mm
Mm
Mm
Range max
Protocol
Mm
Mm
Mm
Mm
(Lin=1000)
Range min
.
(Linear=0)
Serial
.
Communications
.& & & &
Bit Rate
' ' ' ' .( ( ( (
' ' ' '.
Comms Address
1 to 255 (Modbus), 1 to 99 (ASCII)
Ww
Ww
Ww
Ww
Comms Write
Configuration
) ) ) )
Lock Code
R/max
Notes: Output 1 is always a Latching Limit Relay output.
If Option Slot A has the Digital Input module fitted, this always functions as a
Remote Reset, duplicating the function of the Reset) key
R/min
As these functions cannot be changed, no Configuration menus are required.
CAUTION:
Process Variable Offset can be used to modify the
measured value to compensate for probe errors. Positive values
increase the reading, negative values are subtracted. This parameter
is effectively, a calibration adjustment and MUST be used with care.
There is no front panel indication of when this parameter is in use.
Range Max
Range Min
Adjustment range & Description
Default
Value
Range Max
Range Min
Options as for alarm 1
Limit Output Relay
Alarm 1, Direct
Alarm 1, Reverse
Alarm 2, Direct
Alarm 2, Reverse
" " " "
Logical Alarm 1 OR 2, Direct
Logical Alarm 1 OR 2, Reverse
Logical Alarm 1 AND 2, Direct
Logical Alarm 1 AND 2, Reverse
Limit Annunciator, Direct
Limit Annunciator, Reverse
Retransmit Limit SP Output
Retransmit PV Output
0 to 5 V DC output 1
0 to 10 V DC output
2 to 10 V DC output
0 to 20 mA DC output
4 to 20 mA DC output
-1999 to 9999
Range max
will be maximum)
-1999 to 9999
Range min
will be minimum)
" " " "
As for output 2
As for output 2
-1999 to 9999
Range max
will be maximum)
-1999 to 9999
Range min
will be minimum)
PV is visible in Operator mode
PV not visible in Operator mode
Displays
in Operator mode
when Limit Output is not active
ASCII
Modbus with no parity
Mm
Mm
Mm
Mm
Modbus with Even Parity
Modbus with Odd Parity
1.2 kbps
2.4 kbps
.& & & &
4.8 kbps
9.6 kbps
19.2 kbps
Read/Write
Ww
Ww
Ww
Ww
Read only
0 to 9999
.

Advertisement

loading

Summary of Contents for Intel P8700 - Core 2 Duo Processor

  • Page 1 Panel-Mounting Parameter Lower Upper Adjustment range & Description Default 2. SELECT MODE DIN LIMIT CONTROLLERS Display Display Value The mounting panel must be rigid, and may be up to 6.0mm (0.25inch) thick. Cut-out sizes are: Select mode is used to access the configuration and operation menu functions. Alarm 2 Type* CONCISE PRODUCT MANUAL (59333-2) It can be accessed at any time by holding down...
  • Page 2 9. SPECIFICATIONS 4. SETUP MODE 6. ERROR/FAULT INDICATIONS UNIVERSAL INPUT Note: Configuration must be completed before adjusting Setup parameters. Parameter Upper Lower Description First select Setup mode from Select mode (refer to section 2). The Setup LED ±0.1% of full range, ±1LSD (±1° C for Thermocouple CJC). Display Display Thermocouple...

This manual is also suitable for:

P8700 2