2.2

Power Requirements

MODEL
FPRE14
FPRE14
FPRE14
FPRE14
FPRE14
FPRE14
FPRE17
FPRE17
FPRE17
FPRE17
FPRE17
FPRE17
FPRE22
FPRE22
FPRE22
FPRE22
FPRE22
FPRE22
MODEL
FPRE14
FPRE14
FPRE14
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
This appliance must be connected to a power supply having the same voltage and
phase as specified on the rating plate located on the inside of the appliance door.
All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance.
affixed to the inside of the appliance door when installing or servicing this
equipment.
2.3
After Fryers Are Positioned At the Frying Station
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster Dean Service
Hotline at 1-800-551-8633.
Three (3) Phase Requirements
MINIMUM WIRE
WIRE
VOLTAGE
SERVICE
AWG
208
3
240
3
480
3
220/380
4
240/415
4
230/400
4
208
3
240
3
480
3
220/380
4
240/415
4
230/400
4
208
3
240
3
480
3
220/380
4
240/415
4
230/400
4
Single Phase Requirements
MINIMUM WIRE
WIRE
VOLTAGE
SERVICE
AWG
208
2
240
2
480
2
NOTICE
DANGER
DANGER
DANGER
2-3
AMPS
SIZE
(per leg)
(mm)
6
(4.11)
39
6
(4.11)
34
8
(2.59)
17
6
(4.11)
21
6
(4.11)
20
6
(4.11)
21
6
(4.11)
48
6
(4.11)
41
6
(4.11)
21
6
(4.11)
26
6
(4.11)
24
6
(4.11)
25
4
(5.19)
61
4
(5.19)
53
6
(4.11)
27
6
(4.11)
34
6
(4.11)
31
6
(4.11)
32
AMPS
SIZE
(per leg)
(mm)
3
(5.83)
68
4
(5.19)
59
8
(3.26)
30